Rim-to-Disc Ratio Outperforms Cup-to-Disc Ratio for Glaucoma Prescreening
Open Access
- 8 May 2019
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-9
Abstract
We present a novel and fully automated fundus image processing technique for glaucoma prescreening based on the rim-to-disc ratio (RDR). The technique accurately segments the optic disc and optic cup and then computes the RDR based on which it is possible to differentiate a normal fundus from a glaucomatous one. The technique performs a further categorization into normal, moderate, or severely glaucomatous classes following the disc-damage-likelihood scale (DDLS). To the best of our knowledge, this is the first engineering attempt at using RDR and DDLS to perform glaucoma severity assessment. The segmentation of the optic disc and cup is based on the active disc, whose parameters are optimized to maximize the local contrast. The optimization is performed efficiently by means of a multiscale representation, accelerated gradient-descent, and Green’s theorem. Validations are performed on several publicly available databases as well as data provided by manufacturers of some commercially available fundus imaging devices. The segmentation and classification performance is assessed against expert clinician annotations in terms of sensitivity, specificity, accuracy, Jaccard, and Dice similarity indices. The results show that RDR based automated glaucoma assessment is about 8% to 10% more accurate than a cup-to-disc ratio (CDR) based system. An ablation study carried out considering the ground-truth expert outlines alone for classification showed that RDR is superior to CDR by 5.28% in a two-stage classification and about 3.21% in a three-stage severity grading.Keywords
Funding Information
- IMPRINT India #6013
This publication has 35 references indexed in Scilit:
- The Colored Glaucoma Graph and Its Use in Caring for Patients with Glaucoma: A New System of Management, Presented in Three PartsJournal of Current Glaucoma Practice, 2010
- Correlation between Disc Damage Likelihood Scale and Optical Coherence Tomography in the Diagnosis of GlaucomaOphthalmologica, 2010
- Performance measure characterization for evaluating neuroimage segmentation algorithmsNeuroImage, 2009
- Optic Disk Size and GlaucomaSurvey of Ophthalmology, 2007
- Regional Correlation of Structure and Function in Glaucoma, Using the Disc Damage Likelihood Scale, Heidelberg Retina Tomograph, and Visual FieldsOphthalmology, 2006
- Comparison of disc damage likelihood scale, cup to disc ratio, and Heidelberg retina tomograph in the diagnosis of glaucomaBritish Journal of Ophthalmology, 2006
- Disc damage likelihood scaleBritish Journal of Ophthalmology, 2006
- The number of people with glaucoma worldwide in 2010 and 2020British Journal of Ophthalmology, 2006
- Factors affecting the test-retest variability of Heidelberg retina tomograph and Heidelberg retina tomograph II measurementsBritish Journal of Ophthalmology, 2005
- Fast and robust optic disc detection using pyramidal decomposition and Hausdorff-based template matchingIEEE Transactions on Medical Imaging, 2001