The Effect of Under-Reaming on the Cup/Bone Interface of a Press Fit Hip Replacement
Authors:
- 19 March 2010
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 132 (4) , 041008
Abstract
This paper explores the effect of under-reaming on micromotion at the cup/bone interface of a press-fit acetabular cup. A cadaver experiment was performed on 11 acetabuli implanted with a cementless acetabular cup. The loading profile simulated hip impingement at the extremes of motion and subluxation relocation of the hip joint. Micromotion of each cup was measured in a custom made jig with linear variable differential transducers. A CAT scan and DEXA scan of the acetabulum and femoral head respectively were used to construct a three-dimensional patient specific finite element model of the hemi-pelvis. The model predicted cup micromotion under loading conditions and stresses in the acetabulum as a result of cup insertion. Micromotion was then calculated as a function of variable bone density and variable degree of underreaming. Simulated cup insertion with under-reaming of 2 mm or more approached or exceeded the yield strength of bone in acetabula with reduced bone mass density.Keywords
This publication has 15 references indexed in Scilit:
- L5 Radiculopathy Secondary to Intrapelvic Placement of Acetabular Cup Fixation ScrewJournal of Spinal Disorders & Techniques, 2005
- Apparent bone mineral density estimated from DXA in healthy men and womenOsteoporosis International, 2003
- “In vivo” determination of hip joint separation and the forces generated due to impact loading conditionsJournal of Biomechanics, 2001
- The effect of interfacial parameters on cup–bone relative micromotionsJournal of Biomechanics, 2001
- Acetabular fracture associated with cementless acetabular component insertionThe Journal of Arthroplasty, 1999
- Einflußgrößen der Primärstabilität acetabulärer Komponenten. - Eine In-vitro-Studie - Factors Influencing Initial Stability of Uncemented Acetabular Components. An in-vitro StudyBiomedical Engineering / Biomedizinische Technik, 1997
- Differences in stiffness of the interface between a cementless porous implant and cancellous bone in vivo in dogs due to varying amounts of implant motionThe Journal of Arthroplasty, 1996
- A quantitative in vitro assessment of fit and screw fixation on the stability of a cementless hemispherical acetabular componentThe Journal of Arthroplasty, 1994
- Vascular injury during total hip arthroplasty: the anatomy of the acetabulumInternational Orthopaedics, 1994
- Acetabular micromotion as a measure of initial implant stability in primary hip arthroplastyThe Journal of Arthroplasty, 1992