Tibiofemoral Contact Behavior Is Improved in High-flexion Cruciate Retaining TKA
Authors:
- Peter G SultanPSPeter G Sultan
- Sang Eun ParkSPSang Eun Park
- Ramprasad PapannagariRPRamprasad Papannagari
- Guoan LiGLGuoan Li
- 1 November 2006
- journal article
- section i
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 452, 59-64
Abstract
Recently, total knee arthroplasty (TKA) designs have been modified to prevent edge loading on the posterior tibial articular surface and increase the tibiofemoral contact area at high degrees of flexion. The expected improvement in contact behavior of high-flexion TKA over conventional design is not well documented. We ascertained peak contact locations and contact areas of a conventional and a high-flexion cruciate-retaining TKA design. Both TKAs showed similar kinematics throughout the range of flexion although their contact behaviors differed: the peak contact point for the high-flexion TKA was located more anteriorly than the conventional TKA for flexion angles greater than 90°. The tibiofemoral contact of both TKAs reached the polyethylene posterior edge at 150°. The contact on conventional TKA reached the polyethylene posterior edge approximately 15° to 30° before the high-flexion TKA. The high flexion TKA exhibited similar contact areas to conventional TKA. While the clinical relevance is unclear, these data suggest high flexion TKA might improve tibiofemoral contact biomechanics if high flexion is achievable.Keywords
This publication has 21 references indexed in Scilit:
- In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplastyJournal of Biomechanics, 2005
- In Vivo Fluoroscopic Analysis Of Fixed-Bearing Total Knee ReplacementsClinical Orthopaedics and Related Research, 2003
- In vivo determination of posterior femoral rollback for subjects having a NexGen posterior cruciate–retaining total knee arthroplastyThe Journal of Arthroplasty, 2002
- Biomechanics of Posterior-Substituting Total Knee Arthroplasty: An In Vitro StudyClinical Orthopaedics and Related Research, 2002
- In vivo comparison of femorotibial contact positions for Press-Fit posterior stabilized and posterior cruciate–retaining total knee arthroplastiesThe Journal of Arthroplasty, 2002
- Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002
- In Vivo Anteroposterior Femorotibial Translation of Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- Range of motion after total knee arthroplasty The effect of implant design and weight-bearing conditionsThe Journal of Arthroplasty, 1998
- Kinematics of the knee joint in deep flexion: a radiographic assessmentMedical Engineering & Physics, 1998
- Range of Motion in Total Knee ReplacementClinical Orthopaedics and Related Research, 1996