Observation and Quantification of Gas Bubble Formation on a Mechanical Heart Valve
Authors:
- 22 March 2000
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 122 (4) , 304-309
Abstract
Clinical studies using transcranial Doppler ultrasonography in patients with mechanical heart valves (MHV) have detected gaseous emboli. The relationship of gaseous emboli release and cavitation on MHV has been a subject of debate in the literature. To study the influence of cavitation and gas content on the formation and growth of stable gas bubbles, a mock circulatory loop, which employed a Medtronic-Hall pyrolytic carbon disk valve in the mitral position, was used. A high-speed video camera allowed observation of cavitation and gas bubble release on the inflow valve surfaces as a function of cavitation intensity and carbon dioxide concentration, while an ultrasonic monitoring system scanned the aortic outflow tract to quantify gas bubble production by calculating the gray scale levels of the images. In the absence of cavitation, no stable gas bubbles were formed. When gas bubbles were formed, they were first seen a few milliseconds after and in the vicinity of cavitation collapse. The volume of the gas bubbles detected in the aortic track increased with both increased and increased cavitation intensity. No correlation was observed between concentration and bubble volume. We conclude that cavitation is an essential precursor to stable gas bubble formation, and the most soluble blood gas, is the major component of stable gas bubbles. [S0148-0731(00)00204-1]
Keywords
This publication has 19 references indexed in Scilit:
- Oxygen Inhalation Can Differentiate Gaseous From Nongaseous Microemboli Detected by Transcranial Doppler UltrasoundStroke, 1997
- Incidence and Frequency of Cerebral Embolic Signals in Patients With a Similar Bileaflet Mechanical Heart ValveStroke, 1995
- Spontaneously appearing microbubbles associated with prosthetic cardiac valves detected by transesophageal echocardiographyAmerican Heart Journal, 1994
- A Method for Real-Time In Vitro Observation of Cavitation on Prosthetic Heart ValvesJournal of Biomechanical Engineering, 1994
- Prevalence and characteristics of intracranial microemboli signals in patients with different types of prosthetic cardiac valves.Stroke, 1994
- Quantification of ultrasound emboli signals in patients with cardiac and carotid disease.Stroke, 1993
- Spontaneous echocardiographic contrast with the carbomedics mitral valve prosthesisThe American Journal of Cardiology, 1992
- Survey of literature related to the problems of gas embolism in human bodyJournal of Biomechanics, 1969
- Air Embolism Eight Hours after VentriculographyActa Radiologica, 1952
- INJECTIONS OF AIR AND OF CARBON DIOXIDE INTO A PULMONARY VEINAnnals of Surgery, 1940