Electroencephalography Signal Power Spectral Density from Measurements in Room with and Without Faraday Cage: A Comparative Study
Authors:
- SuprijadiSUSuprijadi
Open Access
- 1 June 2022
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2243 (1)
Abstract
Electroencephalography (EEG) is a method for recording the brain’s electrical activity through electrodes placed on the scalp’s surface. This EEG has its problem, namely signal interference from outside the system or artifacts. Ways to eliminate this signal interference can be made in various ways, including handling signal sources outside the system or removing interference signals during the EEG signal processing process. One way is to isolate the measurement room from signal interference using a Faraday cage. In this study, we will compare the results of EEG signal processing in the form of power spectral density (PSD) from measurements in a room without a Faraday cage and a room with a Faraday cage. We find that the average value of the change in PSD from the measurement results in the two rooms had a level of difference that varied between 0.71%-66%. The location of the electrodes that have a high difference value is the frontal and parietal areas.Keywords
This publication has 17 references indexed in Scilit:
- Human brain arousal in the resting state: a genome-wide association studyMolecular Psychiatry, 2018
- Review of the Neural Oscillations Underlying MeditationFrontiers in Neuroscience, 2018
- Brain Rhythms of PainTrends in Cognitive Sciences, 2017
- American Clinical Neurophysiology Society Guideline 1: Minimum Technical Requirements for Performing Clinical ElectroencephalographyJournal Of Clinical Neurophysiology, 2016
- Noise Reduction in Brainwaves by Using Both EEG Signals and Frontal Viewing Camera ImagesSensors, 2013
- Analysis of Electroencephalography (EEG) Signals and Its Categorization–A StudyProcedia Engineering, 2012
- THE NONLINEAR AND NONSTATIONARY PROPERTIES IN EEG SIGNALS: PROBING THE COMPLEX FLUCTUATIONS BY HILBERT–HUANG TRANSFORMAdvances in Adaptive Data Analysis, 2009
- Amygdala–frontal connectivity during emotion regulationSocial Cognitive and Affective Neuroscience, 2007
- Claustrophobia and the Magnetic Resonance Imaging ProcedureJournal of Behavioral Medicine, 1998
- Assessment of digital EEG, quantitative EEG, and EEG brain mapping: Report of the American Academy of Neurology and the American Clinical Neurophysiology Society* [RETIRED]Neurology, 1997