Abstract
The reduction of metal artifacts remains a challenge in computed tomography because they decrease image quality, and consequently might affect the medical diagnosis. The objective of this study is to present a novel method to correct metal artifacts based solely on the CT-slices. The proposed method consists of four steps. First, metal implants in the original CT-slice are segmented using an entropy based method, producing a metal image. Second, a prior image is acquired using three transformations: Gaussian filter, Parisotto and Schoenlieb inpainting method with the Mumford-Shah image model and L0 Gradient Minimization method (L0GM). Next, based on the projections from the original CT-slice, prior image and metal image, the sinogram is corrected in the traces affected by metal in the process called normalization and denormalization. Finally, the reconstructed image is obtained by FBP and a Nonlocal Means (NLM) filtering. The efficacy of the algorithm is evaluated by comparing five image quality metrics of the images and by inspecting regions of interest (ROI). Phantom data as well as clinical datasets are included. The proposed method is compared with three established metal artifact reduction (MAR) methods. The results from a phantom and clinical dataset show the visible reduction of artifacts. The conclusion is that IMIF-MAR method can reduce streak metal artifacts effectively and avoid new artifacts around metal implants, while preserving the anatomical structures. Considering both clinical and phantom studies, the proposed MAR algorithm improves the quality of clinical images affected by metal artifacts, and could be integrated in clinical setting.Keywords
Funding Information
- Deutscher Akademischer Austauschdienst (13GW0095A)
This publication has 45 references indexed in Scilit:
- Efficient and robust nonlocal means denoising of MR data based on salient features matchingComputer Methods and Programs in Biomedicine, 2012
- Image smoothing viaL0gradient minimizationACM Transactions on Graphics, 2011
- Metal artifact reduction in dental CT images using polar mathematical morphologyComputer Methods and Programs in Biomedicine, 2011
- Development, implementation and evaluation of a dedicated metal artefact reduction method for interventional flat-detector CTBritish Journal of Radiology, 2010
- Normalized metal artifact reduction (NMAR) in computed tomographyMedical Physics, 2010
- A Segmentation-Based Method for Metal Artifact ReductionAcademic Radiology, 2007
- An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studiesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- A New Algorithm for Metal Artifact Reduction in Computed TomographyInvestigative Radiology, 2003
- X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prosthesesIEEE Transactions on Medical Imaging, 2000
- Iterative deblurring for CT metal artifact reductionIEEE Transactions on Medical Imaging, 1996