Broadband Cavity Enhanced Absorption Spectroscopy as a Detector for HPLC
- 8 April 2009
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 81 (10) , 4106-4112
Abstract
The first demonstration of a cavity enhanced absorption spectroscopy (CEAS) based technique, applied to HPLC detection is reported. Broadband cavity enhanced absorption spectroscopy (BBCEAS) has been used for detection in a HPLC system (HPLC-BBCEAS). Measurements were made on the dyes rhodamine 6G and rhodamine B between 450 and 600 nm. The sensitivity of the measurements as determined by the minimum detectable change in the absorption coefficient, alpha(min), were 2.9 x 10(-5) cm(-1) at 527 nm and 1.9 x 10(-5) cm(-1) at 556 nm, the peak absorption wavelengths of rhodamine 6G and rhodamine B, respectively. The limits of detection (LOD) for the two dyes were 426 and 271 pM, respectively. The LOD of the HPLC-BBCEAS setup was found to be between 54 and 77 times lower than with a Perkin-Elmer HPLC (series 200) comprising a 200EP photodiode array detector. The sensitivity of the developed setup also compared favorably with the previous single wavelength HPLC-CRDS studies while using a considerably lower cost experimental setup and simpler experimental methodology. The use of BBCEAS detection also allowed the discrimination following an isocratic HPLC separation of the nearly co-eluting dyes rhodamine 6G and rhodamine B.Keywords
This publication has 13 references indexed in Scilit:
- Cavity ring-down spectroscopy for detection in liquid chromatography at UV wavelengths using standard cuvettes in a normal incidence geometryJournal of Chromatography A, 2007
- Cavity Ring-down Spectroscopy for Detection in Liquid Chromatography: Extension to Tunable Sources and Ultraviolet WavelengthsApplied Spectroscopy, 2006
- Improving the sensitivity of HPLC absorption detection by cavity ring-down spectroscopy in a liquid-only cavityAnalytica Chimica Acta, 2005
- Miniaturized Cavity Ring-Down Detection in a Liquid Flow CellAnalytical Chemistry, 2005
- Moving beyond Traditional UV−Visible Absorption Detection: Cavity Ring-Down Spectroscopy for HPLCAnalytical Chemistry, 2005
- Broad-Band Cavity Ring-Down SpectroscopyChemical Reviews, 2003
- Cavity Ring-Down Spectroscopy as a Detector for Liquid ChromatographyAnalytical Chemistry, 2003
- Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopyReview of Scientific Instruments, 1998
- Integrated cavity output analysis of ultra-weak absorptionChemical Physics Letters, 1998
- Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sourcesReview of Scientific Instruments, 1988