Current trends in aortic valve replacement: development of the rapid deployment EDWARDS INTUITY valve system
Authors:
- Michael A BorgerMBMichael A Borger
- Pascal DohmenPDPascal Dohmen
- Martin MisfeldMMMartin Misfeld
- Friedrich W MohrFMFriedrich W Mohr
- 1 July 2013
- journal article
- review article
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 10 (4) , 461-470
Abstract
Although conventional aortic valve replacement (AVR) surgery remains the gold standard for patients with aortic stenosis, transcutaneous aortic valve replacement is becoming increasingly common in high-risk patients. The techniques of minimal invasive surgery (MIS) have been well known for many years, but MIS is applied in a disappointingly low percentage of patients undergoing AVR surgery. The EDWARDS INTUITY rapid deployment aortic valve system is designed to facilitate the performance of MIS AVR surgery. In addition, the reduced implantation times may be beneficial in higher risk patients or those requiring concomitant procedures. The system combines established pericardial valve technology with modern stent expertise obtained from the transcutaneous aortic valve replacement experience. Preliminary results from a multicenter trial have shown low rates of morbidity and mortality, and excellent hemodynamic performance. The EDWARDS INTUITY promises to be an exciting device that may further change the landscape of aortic valve intervention.Keywords
This publication has 59 references indexed in Scilit:
- The Demise of the Stentless ValveSeminars in Thoracic and Cardiovascular Surgery, 2012
- Long-Term Clinical and Hemodynamic Performance of the Hancock II Versus the Perimount Aortic BioprosthesesCirculation, 2010
- Are stentless valves hemodynamically superior to stented valves? Long-term follow-up of a randomized trial comparing Carpentier–Edwards pericardial valve with the Toronto Stentless Porcine ValveThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: Changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National DatabaseThe Journal of Thoracic and Cardiovascular Surgery, 2009
- ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart DiseaseCirculation, 2006
- Outcome of 622 Adults With Asymptomatic, Hemodynamically Significant Aortic Stenosis During Prolonged Follow-UpCirculation, 2005
- Frequency by Decades of Unicuspid, Bicuspid, and Tricuspid Aortic Valves in Adults Having Isolated Aortic Valve Replacement for Aortic Stenosis, With or Without Associated Aortic RegurgitationCirculation, 2005
- Prevalence of aortic valve abnormalities in the elderly: An echocardiographic study of a random population sampleJACC, 1993
- The effect of aortic valve replacement on survival.Circulation, 1982
- Aortic valve replacement with a gaged ball valveThe American Journal of Cardiology, 1962