A Novel Method to Aerosolize Powder for Short Inhalation Exposures at High Concentrations: Isolated Rat Lungs Exposed to Respirable Diesel Soot
Authors:
- 1 January 2004
- journal article
- research article
- Published by Taylor & Francis in Inhalation Toxicology
- Vol. 16 (1) , 45-52
Abstract
More efficient methods are needed to aerosolize dry powders for short-duration inhalation exposures at high concentrations. There is an increasing need to reach the peripheral lung with dry powder medications as well as with collected ambient aerosol particulates in environmental research projects. In a novel aerosol generator, a fixed volume of compressed air was used to create a short burst of a highly concentrated aerosol in a 300-ml holding chamber. Collected diesel soot was deagglomerated to a fine aerosol with a mass median aerodynamic diameter (MMAD) of 0.55 μm, not much larger than the 0.25 μm MMAD of diesel exhaust particles measured in air. A fine powder such as 3-μm silica particles was completely deagglomerated to an aerosol with a MMAD of 3.5 μm. Immediately after generation, the aerosol was available for exposure at a chosen flow rate by the use of an automated valve system. Tritium-labeled diesel soot was thus used to expose the isolated perfused rat lung at an air concentration of ∼3 mg/L and a flow rate of 370 ml/min in a 1-min-long exposure. The lungs were ventilated at 75 breaths/min and a tidal volume of 1.13 ± 0.11 ml (SD, n = 3). Results showed that 19.8 ± 1.1 μg (SD, n = 3) soot was deposited in the lungs. This amount constitutes 9.5% of the amount inhaled and is close to literature data on deposition of similar sized particles in the rat lung. More than 97% of the deposited soot was located distal to the extrapulmonary bronchi, indicating that the system delivers a highly respirable aerosol. The aerosol system is particularly useful for peripheral lung delivery of collected ambient aerosols or dry powder pharmaceuticals following a minimal effort in formulation of the powder.Keywords
This publication has 26 references indexed in Scilit:
- Urban Air Pollution and Lung Cancer in StockholmEpidemiology, 2000
- Inhaled insulin1Abbreviations: DM, diabetes mellitus; AIDs, acquired immune deficiency syndrome; SC, subcutaneous; DCCT, Diabetes Control and Complications Trial; IDDM, insulin-dependent diabetes mellitus; NIDDM, non-insulin-dependent diabetes mellitus; i.v., intravenous; DDPC, di-decanoyl-alpha-phosphatidylcholine; AUC, area under the curve; INH, inhaled; Cmax, maximum serum concentration; Cmin, minimum serum concentration; Tmax, time of maximum serum concentration; NS, not significant; HbA1c, hemoglobin A1c; OA, oral agent; SD, standard deviation; MDI, metered dose inhaler; DPI, dry powder inhaler; MMAD, mass median aerodynamic diameter; CMC, critical micelle concentration; SR, sustained release; PLGA, poly lactic acid-co-glycolic acid; GI, gastrointestinal, GSD, geometric standard deviation; TLC, total lung capacity; VC, vital capacity; SMK, smokers; MW, molecular weight; MP, melting point.1Advanced Drug Delivery Reviews, 1999
- A RAPID COMBUSTION METHOD FOR THE ACCURATE DETERMINATION OF LOW LEVELS OF TRITIUM IN BIOLOGICAL SAMPLESToxicology Mechanisms and Methods, 1998
- Drug Delivery Takes a Deep BreathScience, 1997
- A Multiple-Path Model of Particle Deposition in the Rat LungFundamental and Applied Toxicology, 1995
- A novel dosing method for drug administration to the airways of the isolated perfused rat lungJournal of Pharmaceutical Sciences, 1988
- Lung mechanics of the guinea‐pig isolated perfused lungActa Physiologica Scandinavica, 1986
- A spectrophotometric method for the quantitation of diesel exhaust particles in guinea pig lungJournal of Applied Toxicology, 1981
- The isolated perfused lung — A critical evaluationToxicology, 1981
- A New Dust-Feed MechanismJournal of Scientific Instruments, 1950