Prevention of cochlear implant electrode damage
- 1 October 2006
- journal article
- review article
- Published by Wolters Kluwer Health in Current Opinion in Otolaryngology & Head and Neck Surgery
- Vol. 14 (5) , 323-328
Abstract
As the current trend in cochlear implantation is to prescribe cochlear implants for patients with residual hearing and to use electroacoustic stimulation, cochlear implant damage must be prevented. This article summarizes current research endeavors to prevent electrode insertion trauma and resulting hearing loss. Alteration in surgical technique is necessary with each new electrode design. Nontraumatic surgical technique also requires minimizing acoustic trauma due to drilling the cochleostomy, mechanical damage from electrode insertion, potential infection, and fibrosis of the cochlea. The pattern of hearing loss following electrode insertion trauma is an immediate loss that results from direct trauma to the macroscopic elements of the cochlea and a delayed loss that may reflect the activation of inflammatory and cell death pathways. Therapies under investigation include glucocorticoids, inhibitors of cell death pathways, and hypothermia. Electrode insertion trauma-induced hearing loss involves multiple mechanisms ranging from mechanical insertion trauma to activation of inflammatory and cell death pathways. The macroscopic mechanical damage to the cochlea may be prevented by improvement of electrode design and surgical technique. The molecular damage needs further studies to assess the efficacy of novel therapeutic strategies in preserving functional residual hearing.Keywords
This publication has 23 references indexed in Scilit:
- D-JNKI-1 Treatment Prevents the Progression of Hearing Loss in a Model of Cochlear Implantation TraumaOtology & Neurotology, 2006
- Cochlear implantation trauma and noise‐induced hearing loss: Apoptosis and therapeutic strategiesThe Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology, 2006
- Advanced Bionics Thin Lateral and Helix II Electrodes: A Temporal Bone StudyThe Laryngoscope, 2005
- Evaluation of the Advance Off-Stylet Insertion Technique and the Cochlear Insertion Tool in Temporal BonesOtology & Neurotology, 2005
- Mild Hypothermia Protects Auditory Function During Cochlear Implant SurgeryThe Laryngoscope, 2005
- A Model for Cochlear Implant Electrode Insertion and Force Evaluation: Results with a New Electrode Design and Insertion TechniqueThe Laryngoscope, 2005
- Cochlear temperature correlates with both temporalis muscle and rectal temperatures. Application for testing the otoprotective effect of hypothermiaActa Oto-Laryngologica, 2005
- Cochlear Implantation in Patients with Substantial Residual HearingThe Laryngoscope, 2004
- Cochlear implantation via the round window membrane minimizes trauma to cochlear structures: A histologically controlled insertion studyActa Oto-Laryngologica, 2004
- Mechanisms of Cell Death in the Injured Auditory System: Otoprotective StrategiesAudiology and Neurotology, 2002