Positron Emission Tomography and Computed Tomography in Differential Diagnosis between Recurrent or Residual Glioma and Treatment-Induced Brain Lesions
Authors:
- A. LiljaALA. Lilja
- H. LundqvistHLH. Lundqvist
- Y. OlssonYOY. Olsson
- B. SpännareBSB. Spännare
- P. GullbergPGP. Gullberg
- B. LångströmBLB. Långström
- 1 March 1989
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 30 (2) , 121-128
Abstract
In previous studies of supratentorial gliomas with positron emission tomography (PET) and computed tomography (CT), high uptakes of L-methyl- 11 C-methionine ( 11 C-L-methionine) were found even in astrocytomas without blood-brain barrier defects as judged by CT or 68 Ga-EDTA PET. In a number of patients examined after radiation therapy, there were no consistent changes in the high uptake values. In the present investigation PET and CT were compared with regard to their abilities to visualize and delineate recurrent tumors and treatment-induced brain defects and to differentiate between them. The study was undertaken on four patients who were long-term survivors after treatment for high-grade gliomas. For PET, 11 C-L-methionine and 68 Ga-EDTA were used. In two patients recurrent/residual tumors appeared considerably larger with 11 C-L-methionine PET than with CT or 68 Ga-EDTA PET. In one patient, no signs of recurrence were seen with any of these three methods, and in a fourth patient, whose condition was clinically stable, the findings at PET with 11 C-L-methionine were non-specific. In areas corresponding to the surgical parenchymal defects, the 11 C-L-methionine uptake and, except in one case, the local blood volume was markedly reduced. PET with 11 C-L-methionine thus has a potential for distinguishing between postoperative brain lesions and tumor recurrence with a higher accuracy than CT.Keywords
This publication has 15 references indexed in Scilit:
- Positron Emission Tomography with ([11C]Methyl)-L-Methionine, [11C]D-Glucose, and [68Ga]EDTA in Supratentorial TumorsJournal of Computer Assisted Tomography, 1985
- Immunohistochemistry of central nervous system tumorsJournal of Neurosurgery, 1984
- Discrepancies in Brain Tumor Extent as Shown by Computed Tomography and Positron Emission Tomography Using [68Ga]EDTA, [11C]Glucose, and [11C]MethionineJournal of Computer Assisted Tomography, 1983
- Computerized tomographic and pathologic studies of the untreated, quiescent, and recurrent glioblastoma multiformeJournal of Neurosurgery, 1983
- The Glial Fibrillary Acidic Protein: The Major Protein Constituent of Glial FilamentsScandinavian Journal of Immunology, 1982
- Transient early computed tomographic changes mimicking tumor progression after brain tumor irradiation.Radiology, 1982
- Literature referencesJournal of Computed Tomography, 1981
- Head Fixation Device for Reproducible Position Alignment in Transmission CT and Positron Emission TomographyJournal of Computer Assisted Tomography, 1981
- Computed tomographic evaluation of therapeutically induced changes in primary and secondary brain tumorsNeuroradiology, 1978
- Computed Tomography in the Evaluation of Malignant Glioma Before and After TherapyRadiology, 1976