Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
Authors:
- Sandro Basso BitencourtSandro Basso Bitencourt
- Isabela Araguê CatanozeICIsabela Araguê Catanoze
- Emily Vivianne Freitas da SilvaESEmily Vivianne Freitas da Silva
- Karina Helga Leal TurcioKTKarina Helga Leal Turcio
- Daniela Micheline dos SantosDSDaniela Micheline dos Santos
- Daniela Atili BrandiniDBDaniela Atili Brandini
- Marcelo Coelho GoiatoMGMarcelo Coelho Goiato
- Aimée Maria GuiottiAGAimée Maria Guiotti
Open Access
- 1 January 2021
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 26 (3) , e2119251
Abstract
Objective: This study aimed to evaluate the dimensional stability and maintenance of details of conventional and high stability alginates up to 5-day storage. Methods: Two types of alginates were selected (n=10) for this study, conventional (Hydrogum) and high stability alginates (Hydrogum 5), which were produced with the aid of a cylindrical metal block and a ring-shaped metal mold (Specifications 18, 19, and 25, ANSI/ADA). Ten images were obtained from the molds for the dimensional stability test, which were taken immediately after their production and at each different storage periods (15 min, 24 h, 48 h, 72 h, 96 h, and 120 h) by a digital camera. The specimens were kept hermetically sealed in plastic bags (23°C) and then used to obtain 140 (n=70) dental stone models, used in the detail reproduction test, in which the angular accuracy of three grooves (20 µm, 50 µm, and 75 µm) was observed at each period. The details reproduction accuracy was classified using a predetermined score classification. Measurements of dimensional changes were made in the Corel DRAW X6 program. The data were submitted to the Student’s t-test (α?#8197;= 0.05). Results: A statistically significant difference concerning the size of the matrix was observed after 24h for both alginates, and a statistically significant negative linear dimensional change (contraction) was verified after 24 h of storage (1.52% for the high stability alginate, and 1.32% for the conventional alginate). The high stability alginate kept the full details for 72 hours, while the conventional alginate, for 24 h. Both alginates reproduced the 75 µm groove at all storage periods. Conclusion: Impressions made with both alginates presented satisfactory clinical results when the alginates were immediately poured.Keywords
This publication has 22 references indexed in Scilit:
- A comparison of the marginal fit of crowns fabricated with digital and conventional methodsThe Journal of Prosthetic Dentistry, 2014
- Dimensional changes of extended-pour alginate impression materialsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2013
- Dimensional stability of contemporary irreversible hydrocolloids: Humidor versus wet tissue storageThe Journal of Prosthetic Dentistry, 2012
- The effect of disinfecting solutions on the dimensional stability of dental alginate impression materialsDental Materials, 2012
- Dimensional stability of irreversible hydrocolloid impression materials as a function of pouring time: A systematic reviewThe Journal of Prosthetic Dentistry, 2011
- An in vitro investigation into the physical properties of irreversible hydrocolloid alternativesThe Journal of Prosthetic Dentistry, 2010
- Accuracy of irreversible hydrocolloids (alginates) for fixed prosthodontics, A comparison between irreversible hydrocolloid, reversible hydrocolloid, and addition silicone for use in the syringe‐tray techniqueEuropean Journal of Oral Sciences, 1998
- Department of Veterans Affairs Cooperative Studies Project No. 242. Quantitative and qualitative evaluation of the marginal fit of cast ceramic, porcelain-shoulder, and cast metal full crown marginsThe Journal of Prosthetic Dentistry, 1992
- New American Dental Association Specification No. 25 for Dental Gypsum ProductsThe Journal of the American Dental Association, 1972
- The estimation of cement film thickness by an in vivo techniqueBritish Dental Journal, 1971