Reduction of bias and variance for evaluation of computer‐aided diagnostic schemes
Authors:
- Qiang LiQLQiang Li
- Kunio DoiKDKunio Doi
- 13 March 2006
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 33 (4) , 868-875
Abstract
Computer‐aided diagnostic (CAD) schemes have been developed to assist radiologists in detecting various lesions in medical images. In addition to the development, an equally important problem is the reliable evaluation of the performance levels of various CAD schemes. It is good to see that more and more investigators are employing more reliable evaluation methods such as leave‐one‐out and cross validation, instead of less reliable methods such as resubstitution, for assessing their CAD schemes. However, the common applications of leave‐one‐out and cross‐validation evaluation methods do not necessarily imply that the estimated performance levels are accurate and precise. Pitfalls often occur in the use of leave‐one‐out and cross‐validation evaluation methods, and they lead to unreliable estimation of performance levels. In this study, we first identified a number of typical pitfalls for the evaluation of CAD schemes, and conducted a Monte Carlo simulation experiment for each of the pitfalls to demonstrate quantitatively the extent of bias and/or variance caused by the pitfall. Our experimental results indicate that considerable bias and variance may exist in the estimated performance levels of CAD schemes if one employs various flawed leave‐one‐out and cross‐validation evaluation methods. In addition, for promoting and utilizing a high standard for reliable evaluation of CAD schemes, we attempt to make recommendations, whenever possible, for overcoming these pitfalls. We believe that, with the recommended evaluation methods, we can considerably reduce the bias and variance in the estimated performance levels of CAD schemes.Keywords
Funding Information
- U.S. Public Health Service (CA62625, CA64370)
This publication has 26 references indexed in Scilit:
- Current status and future potential of computer-aided diagnosis in medical imagingBritish Journal of Radiology, 2005
- Computer-Aided Diagnosis of Solid Breast Nodules: Use of an Artificial Neural Network Based on Multiple Sonographic FeaturesIEEE Transactions on Medical Imaging, 2004
- Reduction of false positives on the rectal tube in computer-aided detection for CT colonographyMedical Physics, 2004
- Surface Normal Overlap: A Computer-Aided Detection Algorithm With Application to Colonic Polyps and Lung Nodules in Helical CTIEEE Transactions on Medical Imaging, 2004
- Ideal observer approximation using Bayesian classification neural networksIEEE Transactions on Medical Imaging, 2001
- Classifier design for computer‐aided diagnosis: Effects of finite sample size on the mean performance of classical and neural network classifiersMedical Physics, 1999
- Computerized characterization of masses on mammograms: The rubber band straightening transform and texture analysisMedical Physics, 1998
- Effects of sample size in classifier designIEEE Transactions on Pattern Analysis and Machine Intelligence, 1989
- ROC Methodology in Radiologic ImagingInvestigative Radiology, 1986
- Estimating the Error Rate of a Prediction Rule: Improvement on Cross-ValidationJournal of the American Statistical Association, 1983