Development of a Computer Simulation Model of Intravascular Laser-Tissue Thermal Interaction for Endovenous Laser Ablation
Authors:
- 大阪大学 国際医工情報センター大国大阪大学 国際医工情報センター
- Kunio AwazuKAKunio Awazu
Open Access
- 15 January 2019
- journal article
- Published by Japan Society for Laser Surgery and Medicine in THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE
- Vol. 39 (4) , 293-302
Abstract
Endovenous laser ablation (EVLA) is popular as a less invasive treatment for varicose veins. To reduce undesired side effects, such as postoperative pain and subcutaneous hemorrhage, a semiconductor laser device with a wavelength of 1,470 nm and the ELVeS Radial 2ringTM fiber (CeramOptec, Germany) have been developed. To obtain regulatory approval for such new medical devices in a short period of time and with minimal clinical trials, it is necessary to establish an objective technique for evaluating efficacy and safety in a manner that is not influenced by the operator’s skill. The purpose of this study was to develop a computer simulation model for estimating the intravascular temperature during EVLA and to evaluate the efficacy and safety of the new devices. The simulation was performed under the same irradiation conditions as an ex vivo experiment of EVLA, and validated by comparing the measured and calculated temperatures. When the output power was 7.0 W, the measured peak temperatures were about 90°C and coincided well with the calculated temperatures. On the other hand, when the output power was 10.0 W, the calculated temperatures exceeded 100°C and were higher than the experimental values by 13°C or more. We speculate that the overestimation of the temperature was caused by the latent heat, because vacuolation was observed in the histological images of the venous walls after laser irradiation. Therefore, the results of this simulation are comparable to the measured values. This simulation model should be useful for determining the optimal irradiation condition, and the method of quantitative analysis developed in this study will play a key role in theoretical interpretation of thermal effects during EVLA.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of 1470 nm Laser and Radial 2ring Fiber with 980 nm Laser and Bare-Tip Fiber in Endovenous Laser Ablation of Saphenous Varicose Veins: A Multicenter, Prospective, Randomized, Non-Blind StudyAnnals of Vascular Diseases, 2015
- Morphological Comparison of Denatured Vessel Heated with RF Device and 1470 nm Laser Emitted through Radial-2Ring FiberThe Japanese Journal of Phlebology, 2015
- Ex vivo Investigation of Optimal Irradiation Parameters in Endovenous Laser Ablation at Wavelengths of 980 nm and 1470 nmTHE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE, 2014
- Comparison of Bare-Tip and Radial Fiber in Endovenous Laser Ablation with 1470 nm Diode LaserAnnals of Vascular Diseases, 2014
- Influence of fibers and wavelengths on the mechanism of action of endovenous laser ablationJournal of Vascular Surgery: Venous and Lymphatic Disorders, 2014
- Endvenous Laser Ablation-Basic TechniqueThe Japanese Journal of Phlebology, 2013
- Mechanisms of Action during Endovenous Laser AblationTHE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE, 2012
- Development of Medical Equipment ^|^amp; Regulatory Science- The Definition of the Evaluation System of the Medical by a Science of a Harmonizing Judgement and a Decision with a Society to have Taken Account of a Cost Performance-THE JOURNAL OF JAPAN SOCIETY FOR LASER SURGERY AND MEDICINE, 2012
- Endovenous Laser Ablation: The Role of Intraluminal BloodEuropean Journal of Vascular and Endovascular Surgery, 2011
- MCML—Monte Carlo modeling of light transport in multi-layered tissuesComputer Methods and Programs in Biomedicine, 1995