Evaluation of the Clinical Variables Affecting Attachment Reproduction Accuracy during Clear Aligner Therapy
Open Access
Abstract
Background: The purpose of this study was to evaluate some of the clinical variables that influence the accuracy of reproducing the planned attachment shape. The following clinical variables were considered: the template material, type of composite, and pressure application on the template during attachment curing. Methods: In this study, the evaluated materials for the thermoplastic transfer template construction are Erkolen 0.8 (polyethylene: PE) and Erkodur 0.8 (polyethylene terephthalate glycol—PET-G), and two types of composite resins: Enaflow (light-curing low-viscosity composite resin) and Enamel plus dentina HRI (light-curing high-viscosity composite resin). Two different light-curing lamps were used: Valo cordless color with no pressure and push light pressure (SCS). The 26 models included in the study were imported into the 3 Shape Ortho System 2022 (ver. 85.0.20 3 Shape, Denmark), and attachments were virtually placed on the dental elements of the first premolar and on both sides of the first upper molars. The accuracy of the attachment reproduction was evaluated through linear and angular evaluations against the reference model (MCAD). Three physical models were obtained: model A (MA), which was printed with attachments; model B (MB) with attachments made with a PE template; and model C (MC) with attachments made with a PET-G template. Results: The results showed statistically significant differences (p < 0.05) between the PE and PET-G templates with greater precision using the PET-G template. Statistically significant differences (p < 0.05) were found among the high-viscosity composite and low-viscosity composite with pressure curing. Conclusions: In light of the obtained data, using a PET-G template is recommended. The pressure application during composite curing reduces the reproduction accuracy with a low-viscosity composite.Keywords
This publication has 31 references indexed in Scilit:
- Effect of thermal shrinkage during thermoforming on the thickness of fabricated mouthguards: Part 2 pressure formationDental Traumatology, 2016
- Maxillary molar distalization with aligners in adult patients: a multicenter retrospective studyProgress in Orthodontics, 2016
- Clear Aligners Generations and Orthodontic Tooth MovementJournal of Orthodontics, 2016
- Clear aligners generations and orthodontic tooth movementJournal of Orthodontics, 2016
- Efficacy of clear aligners in controlling orthodontic tooth movement: A systematic reviewThe Angle Orthodontist, 2015
- Treatment outcome and efficacy of an aligner technique – regarding incisor torque, premolar derotation and molar distalizationBMC Oral Health, 2014
- Analysis of the characteristics of slot design affecting resistance to sliding during active archwire configurationsProgress in Orthodontics, 2013
- In vitroevaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignmentThe Korean Journal of Orthodontics, 2012
- How well does Invisalign work? A prospective clinical study evaluating the efficacy of tooth movement with InvisalignAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2009
- Automated custom-manufacturing technology in orthodonticsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003