Abstract
Purpose: To evaluate the safety and efficacy of transscleral cyclophotocoagulation (TSCPC) in patients requiring intraocular pressure (IOP) reduction despite prior Baerveldt glaucoma implant (BGI) surgery. Participants and Methods: Twenty eyes of 20 patients who had previously undergone BGI placement and subsequently underwent TSCPC with the red (810 nm) diode laser between April 2005 and January 2010 were retrospectively reviewed. Results: All patients underwent BGI placement an average of 34.7±24.2 months before TSCPC. The mean follow-up period after TSCPC was 25.6±17.4 months (range, 2.3 to 56.5 mo). IOPs were reduced from a mean of 21.8±4.6 to 10.8±3.2 mm Hg at the most recent follow–up, which represents a 50.2% reduction in mean IOP. Successful postoperative IOP control was achieved in 16 (80%) of 20 patients. The number of glaucoma medications decreased from 4.2±0.6 to 2.2±1.2. The life-table success rate was 78.6% at 12, 24, and 36 months. Postoperative complications included persistent corneal edema in 1 patient and both persistent corneal edema and cystoid macular edema in another patient. Both patients sustained a >2 line reduction in Snellen visual acuity. Conclusions: TSCPC is safe and effective in the management of patients requiring IOP reduction after BGI surgery. Although our sample size was limited, the safety profile of TSCPC after BGI seems promising.Keywords
This publication has 7 references indexed in Scilit:
- Sequential Glaucoma Implants in Refractory GlaucomaAmerican Journal of Ophthalmology, 2010
- Endoscopic and transscleral cyclophotocoagulationBritish Journal of Ophthalmology, 2006
- Influence of Total Energy Delivery on Success Rate after Contact Diode Laser Transscleral Cyclophotocoagulation: A Retrospective Case Review and Meta-analysisJournal of Glaucoma, 2002
- Supplemental transscleral diode laser cyclophotocoagulation after aqueous shunt placement in refractory glaucomaOphthalmology, 2002
- Shunt revision versus additional tube shunt implantation after failed tube shunt surgery in refractory glaucomaAmerican Journal of Ophthalmology, 2000
- One-Year Results of Semiconductor Transscleral Cyclophotocoagulation in Patients With GlaucomaArchives of Ophthalmology (1950), 1993
- Semiconductor Diode Laser Transscleral Cyclophotocoagulation in Patients With GlaucomaAmerican Journal of Ophthalmology, 1992