Surface Characteristics of Esthetic Nickel–Titanium and Beta-Titanium Orthodontic Archwires Produced by Plasma Electrolytic Oxidation (PEO)—Primary Results
Authors:
- Ole JungOJOle Jung
- Jean-Philippe BeckerJBJean-Philippe Becker
- Ralf SmeetsRSRalf Smeets
- Martin GosauMGMartin Gosau
- Germain BeckerGBGermain Becker
- Bärbel Kahl-NiekeBKBärbel Kahl-Nieke
- Anne-Kathrin JungAJAnne-Kathrin Jung
- Max HeilandMax Heiland
- Alexander KoppAKAlexander Kopp
- Mike BarbeckMike Barbeck
- Till KoehneTKTill Koehne
Open Access
Abstract
Background/Aim: There is continuing interest in engineering esthetic labial archwires. The aim of this study was to coat nickel–titanium (NiTi) and beta-titanium (β-Ti), also known as titanium molybdenum (TMA), archwires by plasma electrolytic oxidation (PEO) and to analyze the characteristics of the PEO-surfaces. Materials and Methods: PEO-coatings were generated on 0.014-inch NiTi and 0.19 × 0.25-inch β-Ti archwires. The surfaces were analyzed by scanning electron microscopy and stereomicroscopy. Cytocompatibility testing was performed with ceramized and untreated samples according to EN ISO 10993-5 in XTT-, BrdU- and LDH-assays. The direct cell impact was analyzed using LIVE-/DEAD-staining. In addition, the archwires were inserted in an orthodontic model and photographs were taken before and after insertion. Results: The PEO coatings were 15 to 20 µm thick with a whitish appearance. The cytocompatibility analysis revealed good cytocompatibility results for both ceramized NiTi and β-Ti archwires. In the direct cell tests, the ceramized samples showed improved compatibility as compared to those of uncoated samples. However, bending of the archwires resulted in loss of the PEO-surfaces. Nevertheless, it was possible to insert the β-Ti PEO-coated archwire in an orthodontic model without loss of the PEO-ceramic. Conclusion: PEO is a promising technique for the generation of esthetic orthodontic archwires. Since the PEO-coating does not resist bending, its clinical use seems to be limited so far to orthodontic techniques using straight or pre-bent archwires.Keywords
All Related Versions
This publication has 24 references indexed in Scilit:
- Electrochemical and biological characterization of coatings formed on Ti–15Mo alloy by plasma electrolytic oxidationMaterials Science and Engineering: C, 2014
- Effects of intraoral aging on surface properties of coated nickel-titanium archwiresThe Angle Orthodontist, 2014
- The effect of water storage on the bending properties of esthetic, fiber-reinforced composite orthodontic archwiresThe Angle Orthodontist, 2014
- An investigation into the mechanical and aesthetic properties of new generation coated nickel-titanium wires in the as-received state and after clinical useEuropean Journal of Orthodontics, 2013
- Plasma electrolytic oxidation of titanium and improvement in osseointegrationJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2013
- Force loss in archwire-guided tooth movement of conventional and self-ligating bracketsEuropean Journal of Orthodontics, 2013
- In vivo degradation performance of micro-arc-oxidized magnesium implants: A micro-CT study in ratsActa Biomaterialia, 2013
- Clinical outcomes for patients finished with the SureSmile™ method compared with conventional fixed orthodontic therapyThe Angle Orthodontist, 2011
- Wear resistance of micro-arc oxidation coatings on biomedical NiTi alloyJournal of Alloys and Compounds, 2009