Abstract
Purpose: To assess the feasibility of three‐dimensional breathhold coronary magnetic resonance angiography (MRA) at 3.0T using the steady‐state free precession (SSFP) sequence, and quantify the signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) gains of coronary MRA from 1.5T to 3.0T using whole‐body and phased‐array cardiac coils as the signal receiver.Materials and Methods: Eight healthy volunteers were scanned on 1.5T and 3.0T whole‐body systems using the SSFP sequence. Numerical simulations were performed for the SSFP sequence to optimize the flip angle and predict signal enhancement from 1.5T to 3.0T. Coronary artery images were acquired with the whole‐body coil in transmit‐receive mode or transmit‐only with phased‐array cardiac coil receivers.Results: In vivo studies of the same volunteer group at both field strengths showed increases of 87% in SNR and 83% in CNR from 1.5T to 3.0T using a whole‐body coil as the signal receiver. The corresponding increases using phased‐array receivers were 53% in SNR and 92% in CNR. However, image quality at 3.0T was more variable than 1.5T, with increased susceptibility artifacts and local brightening as the result of increased B0 and B1 inhomogeneities.Conclusion: Coronary MRA at 3.0T using a three‐dimensional breathhold SSFP sequence is feasible. Improved SNR at 3.0T warrants the use of coronary MRA with faster acquisition and/or improved spatial resolution. Further investigations are required to improve the consistency of image quality and signal uniformity at 3.0T. J. Magn. Reson. Imaging 2005;22:206–212.Keywords
This publication has 22 references indexed in Scilit:
- Coronary arteries at 3.0 T: Contrast‐enhanced magnetization‐prepared three‐dimensional breathhold MR angiographyJournal of Magnetic Resonance Imaging, 2005
- Cardiac SSFP imaging at 3 TeslaMagnetic Resonance in Medicine, 2004
- Comparison of Cardiac MRI on 1.5 and 3.0 Tesla Clinical Whole Body SystemsInvestigative Radiology, 2003
- Double inversion black‐blood fast spin‐echo imaging of the human heart: A comparison between 1.5T and 3.0TJournal of Magnetic Resonance Imaging, 2003
- Artifact reduction in true‐FISP imaging of the coronary arteries by adjusting imaging frequencyMagnetic Resonance in Medicine, 2003
- Is TrueFISP a gradient‐echo or a spin‐echo sequence?Magnetic Resonance in Medicine, 2003
- Reduction of transient signal oscillations in true‐FISP using a linear flip angle series magnetization preparationMagnetic Resonance in Medicine, 2002
- Preliminary report on in vivo coronary MRA at 3 Tesla in humansMagnetic Resonance in Medicine, 2002
- Off-resonance correction of MR imagesIEEE Transactions on Medical Imaging, 1999
- Adiabatic refocusing pulse which compensates for variable of power and off‐resonance effectsMagnetic Resonance in Medicine, 1987