Separation and determination of seven fluoroquinolones by pressurized capillary electrochromatography
- 25 October 2005
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 28 (16) , 2210-2217
Abstract
In this paper, pressurized CEC was used for the separation and determination of seven fluoroquinolones (FQs). The effect of different experimental conditions, such as the concentration and pH of the buffer, the organic modifier concentration, the surfactant and ion‐paring agents added to the electrolyte, and applied voltage were studied. All the seven FQs were baseline separated using mobile phase containing 27% v/v ACN, 5 mmol/L Na2HPO4 buffer (pH 4.0 adjusted using citric acid), 11 mmol/L SDS, and 0.01% TEA v/v at detection wavelength of 287 nm and at an applied voltage of –10 kV. The calibration curves were linear (r >0.9991) over a concentration range of 1.0–50.0 mg/L for norfloxacin (NFLX); 2.5–50.0 mg/L for fleroxacin (FLX), ciprofloxacin (CPFX), and lomefloxacin (LMX); and 5.0–50.0 mg/L for enoxacin (ENX), ofloxacin (OFLX), and gatifloxacin (GFLX). The detection limits (S/N = 3) for ENX, OFLX, FLX, NFLX, CPFX, LMX, and GFLX were 0.5, 0.8, 0.4, 0.2, 0.4, 0.5, and 1.0 mg/L, respectively. The method is simple, rapid, and reproducible. It was successfully applied to the analysis of fish muscle samples spiked with FQs. Mean recoveries ranged from 81.6 to 97.6%.Keywords
This publication has 26 references indexed in Scilit:
- Supercritical fluid extraction of the fluoroquinolones norfloxacin and ofloxacin from orally treated-chicken breast musclesAnalytica Chimica Acta, 2004
- Pressurized capillary electrochromatography separation of peptides with strong cation exchange and hydrophilic interactionJournal of Separation Science, 2003
- Separation of pyridazinone derivatives using pressurized gradient capillary electrochromatographyJournal of Microcolumn Separations, 2001
- Residues of antimicrobial drugs and feed additives in animal products: regulatory aspectsLivestock Production Science, 1999
- Experiences with packed capillary electrochromatography at ambient pressureJournal of Chromatography A, 1996
- Pressurized flow electrochromatography with reversed phase capillary columnsAnalytical and Bioanalytical Chemistry, 1995
- Electrochromatography and micro high-performance liquid chromatography with 320 μm I.D. packed columnsJournal of Chromatography A, 1994
- Effects of buffer composition on electroosmotic flow in capillary electrophoresisJournal of Microcolumn Separations, 1990
- High-resolution separations based on electrophoresis and electroosmosisJournal of Chromatography A, 1981
- Electro-osmosisJournal of Chromatography A, 1974