A nonrigid registration method for correcting brain deformation induced by tumor resection
- 1 October 2014
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 41 (10) , 101710
Abstract
Purpose:: This paper presents a nonrigid registration method to align preoperative MRI with intraoperative MRI to compensate for brain deformation during tumor resection. This method extends traditional point‐based nonrigid registration in two aspects: (1) allow the input data to be incomplete and (2) simulate the underlying deformation with a heterogeneous biomechanical model.Methods:: The method formulates the registration as a three‐variable (point correspondence, deformation field, and resection region) functional minimization problem, in which point correspondence is represented by a fuzzy assign matrix; Deformation field is represented by a piecewise linear function regularized by the strain energy of a heterogeneous biomechanical model; and resection region is represented by a maximal simply connected tetrahedral mesh. A nested expectation and maximization framework is developed to simultaneously resolve these three variables.Results:: To evaluate this method, the authors conducted experiments on both synthetic data and clinical MRI data. The synthetic experiment confirmed their hypothesis that the removal of additional elements from the biomechanical model can improve the accuracy of the registration. The clinical MRI experiments on 25 patients showed that the proposed method outperforms the ITK implementation of a physics‐based nonrigid registration method. The proposed method improves the accuracy by 2.88 mm on average when the error is measured by a robust Hausdorff distance metric on Canny edge points, and improves the accuracy by 1.56 mm on average when the error is measured by six anatomical points.Conclusions:: The proposed method can effectively correct brain deformation induced by tumor resection.Keywords
Funding Information
- NSF (CCF-1139864)
- NSF (CCF-1136538)
- NSF (CSI-1136536)
- National Science Foundation (CCF‐1139864)
- National Science Foundation (CCF‐1136538)
- National Science Foundation (CSI‐1136536)
- ARRA funds (NLM A2D2 201000586P)
- National Science Foundation (CCF-1139864, CCF-1136538, CSI-1136536)
This publication has 29 references indexed in Scilit:
- A Sparse Intraoperative Data-Driven Biomechanical Model to Compensate for Brain Shift during NeuronavigationAmerican Journal of Neuroradiology, 2010
- A robust brain deformation framework based on a finite element model in IGNSThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgeryNeuroImage, 2007
- Patient-specific model of brain deformation: Application to medical image registrationJournal of Biomechanics, 2007
- Medical image registration with partial dataMedical Image Analysis, 2006
- A new point matching algorithm for non-rigid registrationComputer Vision and Image Understanding, 2003
- Modeling of Retraction and Resection for Intraoperative Updating of ImagesNeurosurgery, 2001
- Registration of 3-d intraoperative MR images of the brain using a finite-element biomechanical modelIEEE Transactions on Medical Imaging, 2001
- R.A. Fisher and the making of maximum likelihood 1912-1922Statistical Science, 1997
- Principal warps: thin-plate splines and the decomposition of deformationsIEEE Transactions on Pattern Analysis and Machine Intelligence, 1989