Abstract
Background: Motion control and comfort are primary objectives in orthotic intervention. Semicustom orthotic devices have been presented as a more cost-effective solution than custom orthotic devices. However, no studies have compared their function or comfort to that of custom orthotic devices. Methods: Nineteen uninjured runners were fitted for custom and semicustom orthotic devices. Subjects underwent an instrumented gait analysis of running and walking in no-orthotic, custom orthotic, and semicustom orthotic conditions. Subjects completed visual analog scales for the custom and semicustom orthotic conditions. One-way repeated measures analyses of variance were performed on the rearfoot variables of peak eversion, eversion excursion, eversion duration, and eversion velocity. Two-tailed, dependent t tests were used to compare comfort. Results: Eversion excursion showed significant differences between the conditions: during running, it was reduced in the custom orthotic as compared to the no-orthotic condition; during walking, it was reduced in the semicustom orthotic as compared to both the custom and no-orthotic conditions. The custom orthotic devices were significantly more comfortable ( P < .05) than the semicustom devices in the area of the edges only. Conclusion: The results suggest that, in uninjured individuals, there are few differences in rearfoot motion control and comfort between the custom and semicustom orthotic devices used in this study. (J Am Podiatr Med Assoc 98(5): 394–403, 2008)Keywords
This publication has 22 references indexed in Scilit:
- Efficacy of foot orthoses. What does the literature tell us?Journal of the American Podiatric Medical Association, 2000
- The Effect of Foot Structure on the Three-Dimensional Kinematic Coupling Behavior of the Leg and Rear FootPhysical Therapy, 1998
- Effects of Three Different Posting Methods on Controlling Abnormal Subtalar PronationPhysical Therapy, 1994
- Orthoses for athletic overuse injuries. Comparison of two component materialsJournal of the American Podiatric Medical Association, 1993
- Orthotic survey. Preliminary resultsJournal of the American Podiatric Medical Association, 1993
- The Effect of Foot Orthotics and Gait Velocity on Lower Limb Kinematics and Temporal Events of StanceJournal of Orthopaedic & Sports Physical Therapy, 1993
- Effectiveness of orthotic shoe inserts in the long-distance runnerThe American Journal of Sports Medicine, 1991
- Biomechanical Foot Orthotics: A Retrospective StudyJournal of Orthopaedic & Sports Physical Therapy, 1988
- Functional foot orthoses for athletic injuries. A retrospective studyJournal of the American Podiatric Medical Association, 1985
- Orthotics in the Prevention of Runners' Overuse InjuriesThe Physician and Sportsmedicine, 1981