Predictors of Short-Term Complications After Implantable Cardioverter-Defibrillator Replacement
Authors:
- Andrew D. KrahnAKAndrew D. Krahn
- Douglas S. LeeDLDouglas S. Lee
- David BirnieDBDavid Birnie
- Jeffrey S. HealeyJHJeffrey S. Healey
- Eugene CrystalECEugene Crystal
- Paul DorianPDPaul Dorian
- Christopher S. SimpsonCSChristopher S. Simpson
- Yaariv KhaykinYKYaariv Khaykin
- Douglas CameronDCDouglas Cameron
- Amir JanmohamedAJAmir Janmohamed
- Raymond YeeRYRaymond Yee
- Peter C. AustinPAPeter C. Austin
- 1 April 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 4 (2) , 136-142
Abstract
Background—: Complications after implantable cardioverter-defibrillator (ICD) replacement are often clinically devastating, particularly when infection or reoperation occurs. Identifying factors contributing to complications may permit identification of high-risk individuals that warrant incremental monitoring and therapy to attenuate risk. In addition, replacement may be a discretionary decision in the context of an advisory or borderline device performance and patient, device, and implanter factors that predict adverse outcome may assist in clinical decision-making. Methods and Results—: In a prospective, multicenter, population-based registry of all ICD patients at 18 centers in Ontario, Canada, we examined 45-day complication and all-cause mortality rates from February 2007 to August 2009 in patients undergoing ICD generator replacement. Complications were determined longitudinally and were categorized as major or minor. ICD replacement was performed in 1081 of 5176 patients (20.8%) undergoing ICD implantation (age, 64.3±12.7 years; 78.5% men). In patients undergoing ICD replacement, 47 patients (4.3%) had a complication within 45 days, with 47 major complications in 28 patients (2.6%), most commonly infection (n=23), lead revision (n=35), electrical storm (n=14), and pulmonary edema (n=13). Minor complications occurred in 2.3% of patients, most commonly incisional infection (n=10) and pocket hematoma (n=10). On multivariable analysis, risk factors associated with major complications were Canadian Cardiovascular Society angina class (adjusted hazard ratio [HR], 3.70 for class 2 to 4 versus 0 to 1; P =0.027) and multiple previous procedures on the pocket (adjusted HR, 3.35 for >1 versus 1; P =0.058). Risk factors associated with any complication were the use of antiarrhythmic therapy (adjusted HR, 6.29; P =0.001), implanter volume (adjusted HR 10.4 for 120/y, P =0.026), and Canadian Cardiovascular Society angina class (adjusted HR, 3.00 for class 2 to 4 versus 0 to 1; P =0.031). In a Cox model with a time-dependent variable of major complication within 45 days after replacement, major complications after ICD replacement were associated with an increased risk of mortality at 45, 90, and 180 days (adjusted HR, 9.61, 12.69, and 6.41, respectively; P =0.002 to 0.039). Conclusions—: Risk factors associated with complications after ICD replacement include the presence of angina, antiarrhythmic therapy, increased number of previous procedures, and low implanter volume. Major complications may be associated with increased risk of subsequent mortality.Keywords
This publication has 24 references indexed in Scilit:
- Complications of replacing implantable devices in response to advisories: A single center experienceInternational Journal of Cardiology, 2009
- Association of Physician Certification and Outcomes Among Patients Receiving an Implantable Cardioverter-DefibrillatorJAMA, 2009
- Patient and Implanting Physician Factors Associated With Mortality and Complications After Implantable Cardioverter-Defibrillator Implantation, 2002–2005Circulation: Arrhythmia and Electrophysiology, 2008
- Effect of Cardiac and Noncardiac Conditions on Survival After Defibrillator ImplantationJACC, 2007
- ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac DeathJACC, 2006
- Recommendations of the European Cardiac Arrhythmia Society Committee on Device Failures and ComplicationsPacing and Clinical Electrophysiology, 2006
- The Frequency and Incremental Cost of Major Complications Among Medicare Beneficiaries Receiving Implantable Cardioverter-DefibrillatorsJACC, 2006
- Impact of Hospital Volume on Racial Disparities in Cardiovascular Procedure MortalityJACC, 2006
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionThe New England journal of medicine, 2002
- Complications associated with pectoral cardioverter-defibrillator implantation: Comparison of subcutaneous and submuscular approachesJACC, 1996