The Hydrogen Issue in the Initial Operation of a Filtered Containment Venting System

Authors:

Abstract
This study evaluated the hydrogen issue in the initial operation of a filtered containment venting system (FCVS). We calculated the volumetric concentration of hydrogen, steam, and air in the postulated FCVS connected with the OPR 1000, as a target nuclear power plant, under a station blackout using the MELCOR computer code (version 1.8.6). A large amount of steam and a flammable mixture generated during a severe accident are immediately released from the containment building to the FCVS when the pressure in the containment building approaches a set value. The constituent ratio of the flammable mixture of hydrogen, steam, and air can change due to the different thermal-hydraulic conditions between those due to a severe accident in the containment building and the initial condition in the FCVS. The volumetric concentration of hydrogen was 6% in the containment building just before the operation of the FCVS. It increased up to 9% in the FCVS vessel during the early operation, and steam condensation ...