Quantitation of Mandibular Symphysis Volume as a Source of Bone Grafting
- 4 May 2010
- journal article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 12 (2) , 99-104
Abstract
Background: Autogenous intramembranous bone graft present several advantages such as minimal resorption and high concentration of bone morphogenetic proteins. A method for measuring the amount of bone that can be harvested from the symphysis area has not been reported in real patients.Purpose: The aim of the present study was to intrasurgically quantitate the volume of the symphysis bone graft that can be safely harvested in live patients and compare it with AutoCAD® (version 16.0, Autodesk, Inc., San Rafael, CA, USA) tomographic calculations.Materials and Methods: AutoCAD software program quantitated symphysis bone graft in 40 patients using computerized tomographies. Direct intrasurgical measurements were recorded thereafter and compared with AutoCAD data. The bone volume was measured at the recipient sites of a subgroup of 10 patients, 6 months post sinus augmentation.Results: The volume of bone graft measured by AutoCAD averaged 1.4 mL (SD 0.6 mL, range: 0.5–2.7 mL). The volume of bone graft measured intrasurgically averaged 2.3 mL (SD 0.4 mL, range 1.7–2.8 mL). The statistical difference between the two measurement methods was significant. The bone volume measured at the recipient sites 6 months post sinus augmentation averaged 1.9 mL (SD 0.3 mL, range 1.3–2.6 mL) with a mean loss of 0.4 mL.Conclusion: AutoCAD did not overestimate the volume of bone that can be safely harvested from the mandibular symphysis. The use of the design software program may improve surgical treatment planning prior to sinus augmentation.Keywords
This publication has 19 references indexed in Scilit:
- Morbidity after Chin Bone Harvesting – A Retrospective Long‐Term Follow‐Up StudyClinical Implant Dentistry and Related Research, 2009
- Morphometric Analysis of Implant‐Related Anatomy in Caucasian SkullsJournal of Periodontology, 2004
- Evaluation of the Mandible as an Alternative Autogenous Bone Source for Oral and Maxillofacial ReconstructionJournal of International Medical Research, 2002
- A prospective study on changes in the sensibility of the oral mucosa and the mucosa of the upper lip after Le Fort I osteotomyJournal of Cranio-Maxillofacial Surgery, 1994
- Autogenous mandibular bone grafts and osseointegrated implants for reconstruction of the severely atrophied maxilla: A preliminary reportJournal of Oral and Maxillofacial Surgery, 1991
- Evaluation of a microcomputed tomography system to study trabecular bone structureJournal of Orthopaedic Research, 1990
- The direct examination of three-dimensional bone architecture in vitro by computed tomographyJournal of Bone and Mineral Research, 1989
- Neurosensory disturbance with rigid fixation of the bilateral sagittal split osteotomyJournal of Oral and Maxillofacial Surgery, 1987
- Membranous versus Endochondral BonePlastic and Reconstructive Surgery, 1983
- Repair of Bone GraftsScandinavian Journal of Plastic and Reconstructive Surgery, 1980