On the Dominant Harmonic Source Identification— Part I: Review of Methods
- 13 September 2017
- journal article
- review article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (3) , 1268-1277
Abstract
Analyzing the harmonic distortions at the point of common coupling is thoroughly addressed in this two-part paper. The main aim of such an analysis is to identify which of the utility and customer sides is significantly responsible for the harmonic distortions at the point of common coupling. In Part I, the meaning of the dominant side is challenged fundamentally. Here, two different definitions for the dominant side are discussed: The side with the larger equivalent harmonic “voltage” or “current” source. It is shown that these definitions are not identical. Subsequently, common methods are categorized in three general concepts based on: the direction of active power flow, the reactive power, and the voltage-current ratio. These three categories as well as their validity are analytically reviewed for both the definitions. The concept based on the voltage-current ratio has been explicitly presented in the original work for identifying the dominant equivalent harmonic voltage source. This concept is developed in this paper for identifying the dominant equivalent harmonic current source as well. In Part II, the application of the methods is illustrated using some common calculation examples. In addition, these methods are described verbally to provide a physical interpretation. Some practical aspects regarding the implementation of the methods are discussed as well.Keywords
This publication has 13 references indexed in Scilit:
- A novel approach to analyze the harmonic behavior of customers at the point of common coupling2015
- Identifying harmonic sources on the power grid - some technical challenges2005
- A “Critical Impedance”-Based Method for Identifying Harmonic SourcesIEEE Transactions on Power Delivery, 2004
- An investigation on the validity of power-direction method for harmonic source determinationIEEE Transactions on Power Delivery, 2003
- Power direction method cannot be used for harmonic source detection2002
- A method for determining customer and utility harmonic contributions at the point of common couplingIEEE Transactions on Power Delivery, 2000
- On techniques for localization of sources producing distortion in three‐phase networksEuropean Transactions on Electrical Power, 1996
- A new method of harmonic power detection based on the instantaneous active power in three-phase circuitsIEEE Transactions on Power Delivery, 1995
- Harmonic power flow analysis for the measurement of the electric power qualityIEEE Transactions on Instrumentation and Measurement, 1995
- On techniques for localization of sources producing distortion in electric power networksEuropean Transactions on Electrical Power, 1994