Fabrication and performance of a high resolution ultra-short period W/B4C multilayer structure
Authors:
- 29 February 2016
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 49 (13) , 135305
Abstract
Microstructure limited reflectivity of sputter deposited ultra-short period W/B 4 C multilayers (MLs) has been studied using x-ray reflectivity, diffuse scattering and transmission electron microscopy (TEM). In order to understand the W-B 4 C interface in the near-discontinuous range, the thickness of the constituent layers was systematically varied between 0.5 nm and 2.5 nm. Good density contrast and minimal thickness error were observed in MLs with individual layer thickness higher than ~1.1 nm. However, below 1.1 nm one enters into a regime where the individual layers become discontinuous, leading to embedded growth of the two constituent layers. Consequently, a significant loss of x-ray contrast was observed. In addition, increased area of contact between W and B 4 C enhances the fraction of tungsten compound resulting in a layer thickness error. Based on these findings, large repetition (upto 400 bilayers) MLs with ultra-short period (down to 1.6 nm) were optimized to achieve reflectivity as high as 53% and resolving power of 149, at 8.047 keV.Keywords
This publication has 40 references indexed in Scilit:
- Ultra-short-period WC/SiC multilayer coatings for x-ray applicationsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- A double multilayer monochromator for the B16 Test beamline at the Diamond Light Source2011
- A single W/B_4C transmission multilayer for polarization analysis of soft x-rays up to 1keVOptics Express, 2009
- Reflectance and Resolution of Multilayer Monochromators for Photon Energies from 400 – 6000 eVAIP Conference Proceedings, 2007
- A sagittally focusing double-multilayer monochromator for ultrafast X-ray imaging applicationsJournal of Synchrotron Radiation, 2006
- Ultrashort period Cu/Si and Ni/C multilayers for X-ray mirrorsZeitschrift für Kristallographie Supplements, 2006
- Performance of a double-multilayer monochromator at Beamline 2-BM at the Advanced Photon SourceReview of Scientific Instruments, 2002
- Performance of the double multilayer monochromator on the NSLS wiggler beam line X25AIP Conference Proceedings, 1997
- Synthesis and measurement of normal incidence X-ray multilayer mirrors optimized for a photon energy of 390 eVNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994
- High-performance Mo/Si and W/BC multilayer mirrors for soft X-ray imaging opticsJournal of X-Ray Science and Technology, 1994