Advantages of Extended Brain Perfusion Computed Tomography
Authors:
- Dominik MorhardDMDominik Morhard
- Christina D. WirthCWChristina D. Wirth
- Gunther FeslGFGunther Fesl
- Caroline SchmidtCSCaroline Schmidt
- Maximilian F. ReiserMRMaximilian F. Reiser
- Christoph R. BeckerCBChristoph R. Becker
- Birgit Ertl-WagnerBEBirgit Ertl-Wagner
- 1 July 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 45 (7) , 363-369
Abstract
Recent technical developments have led to an extension of perfusion computed tomography (PCT) scan range to cover nearly the entire brain and to reconstruct time resolved (4d) CT-angiography (CTA) datasets from the PCT data. The purpose of this study was to compare the results of simulated standard PCT and extended PCT with 4d-CTA. Extended multimodal stroke CT (unenhanced cranial CT, CTA, and PCT) was acquired in 72 patients. PCT images with a scan coverage of 9.6 cm in the z-axis, simulated 2 cm PCT images at the level of the basal ganglia comparable to standard PCT, standard supra-aortic CTA, and 4d-CTA images were reconstructed. Two readers assessed the PCT image quality as well as pathologic findings in extended and simulated PCT, CTA, and 4d-CTA. The brain was divided into 4 axial segments. The independent samples t test was applied to test differences between data for significance. In 75.0% of all patient exams, pathologic findings were observed in the PCT; these were located in 138 brain segments. In 24.1% of all 54 exams with pathologic PCT findings, the pathology would have been missed on standard PCT. The longer scan coverage resulted in a different final diagnosis in 34.7% of all exams. Quality of the PCT parameter maps was on average very good both for the supratentoric and the infratentoric brain areas (4.28 and 4.18, respectively, on a 5-point scale). In 90% of all exams with pathologic changes in the CTA, these abnormalities were also noted on 4d-CTA. In only 2.8% of all cases, the additional time resolution of the 4d-CTA provided additional information. Extending the scan coverage of PCT from 2 cm to 9.6 cm led to an augmentation of clinically important information in the imaging of acute stroke.Keywords
This publication has 14 references indexed in Scilit:
- Optimal Brain Perfusion CT Coverage in Patients with Acute Middle Cerebral Artery StrokeAmerican Journal of Neuroradiology, 2009
- Steroid-Responsive Large Vessel Vasculitis: Application of Whole-Brain 320-Detector Row Dynamic Volume CT Angiography and PerfusionAmerican Journal of Neuroradiology, 2009
- Quantitative Assessment of Core/Penumbra Mismatch in Acute StrokeStroke, 2008
- Perfusion CT of the Brain Using 40-mm-Wide Detector and Toggling Table Technique for Initial Imaging of Acute StrokeAmerican Journal of Roentgenology, 2008
- Guidelines for Management of Ischaemic Stroke and Transient Ischaemic Attack 2008Cerebrovascular Diseases, 2008
- Systematic comparison of perfusion‐CT and CT‐angiography in acute stroke patientsAnnals of Neurology, 2007
- Perfusion-CT Assessment of Infarct Core and PenumbraStroke, 2006
- Brain perfusion-CT in acute stroke patientsEuropean Radiology Supplements, 2005
- Quantitative Assessment of the Ischemic Brain by Means of Perfusion-Related Parameters Derived From Perfusion CTStroke, 2001
- Perfusion measurements of the brain: using dynamic CT for the quantitative assessment of cerebral ischemia in acute strokeEuropean Journal of Radiology, 1999