Evaluation of aqueous Na{sup +}/Cs{sup +} separation by electrodialysis

Authors:
  • MBM.F. Buehler
    M.F. Buehler
  • WLW.E. Lawrence
    W.E. Lawrence
  • JNJ.D. Norton
    J.D. Norton

Abstract
In support of the Hanford Site cleanup, electrodialysis is being investigated as a method to separate aqueous sodium (Na{sup +}) and cesium (Cs{sup +}) ions. The approach has many advantages over existing separation technologies; in particular, electrodialysis creates little secondary waste while producing usable acid and base streams. The fundamentals of electrodialysis are presented in this report to provide a foundation for interpreting experimental data. A flat-plate laboratory-scale apparatus was used to determine the feasibility of separating Na{sup +}/Cs{sup +} mixtures by electrodialysis. The results showed that Cs{sup +} is preferentially separated over Na{sup +} by a factor of 2 to 3 using a Nafion{reg_sign} 417 cationic membrane. The separation is relatively insensitive to solution ionic strength and flow-rate variations. The current efficiency of the separation ranges from 0.60 to 0.65 depending on the applied voltage. The laboratory-scale system was characterized by dimensional analysis, which demonstrated that the process could be scaled up to a size attractive for the volume of waste at the Hanford Site. Preliminary experiments on a bench-scale system were also conducted. The initial results showed that the current-voltage response of the laboratory- and the bench-scale unit is identical.
Funding Information
  • USDOE, Washington, DC (United States)
  • DOE (AC06-76RL01830)