Landmark‐based augmented reality system for paranasal and transnasal endoscopic surgeries
- 21 July 2009
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 5 (4) , 415-422
Abstract
Background: In this paper we present a landmark‐based augmented reality (AR) endoscope system for endoscopic paranasal and transnasal surgeries along with fast and automatic calibration and registration procedures for the endoscope.Methods: Preoperatively the surgeon selects natural landmarks or can define new landmarks in CT volume. These landmarks are overlaid, after proper registration of preoperative CT to the patient, on the endoscopic video stream. The specified name of the landmark, along with selected colour and its distance from the endoscope tip, is also augmented. The endoscope optics are calibrated and registered by fast and automatic methods. Accuracy of the system is evaluated in a metallic grid and cadaver set‐up.Results: Root mean square (RMS) error of the system is 0.8 mm in a controlled laboratory set‐up (metallic grid) and was 2.25 mm during cadaver studies.Conclusions: A novel landmark‐based AR endoscope system is implemented and its accuracy is evaluated. Augmented landmarks will help the surgeon to orientate and navigate the surgical field. Studies prove the capability of the system for the proposed application. Further clinical studies are planned in near future. Copyright © 2009 John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Image‐enhanced surgical navigation for endoscopic sinus surgery: evaluating calibration, registration and trackingThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- Design and clinical evaluation of an image-guided surgical microscope with an integrated tracking systemInternational Journal of Computer Assisted Radiology and Surgery, 2007
- Tracking endoscopic instruments without a localizer: A shape-analysis-based approachComputer Aided Surgery, 2007
- Tracking endoscopic instruments without a localizer: A shape-analysis-based approachComputer Aided Surgery, 2007
- Endoscopic Augmented Reality Navigation System for Endonasal Transsphenoidal Surgery to Treat Pituitary Tumors: Technical NoteNeurosurgery, 2002
- Image‐Guided Functional Endoscopic Sinus SurgeryOtolaryngology–Head and Neck Surgery, 2000
- Utilizing Segmented MRI Data in Image-Guided SurgeryInternational Journal of Pattern Recognition and Artificial Intelligence, 1997
- Image-guided endoscopic ENT surgeryEuropean Archives of Oto-Rhino-Laryngology, 1997
- Augmentation of Reality Using an Operating Microscope for Otolaryngology and Neurosurgical GuidanceComputer Aided Surgery, 1995
- Merging virtual objects with the real worldACM SIGGRAPH Computer Graphics, 1992