Optimizing Native Ion Mobility Q-TOF in Helium and Nitrogen for Very Fragile Noncovalent Structures
- 25 July 2018
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 29 (11) , 2189-2198
Abstract
The amount of internal energy imparted to the ions prior to the ion mobility cell influences the ion structure and thus the collision cross section. Non-covalent complexes with few internal degrees of freedom and/or high charge densities are particularly sensitive to collisional activation. Here, we investigated the effects of virtually all tuning parameters of the Agilent 6560 IM-Q-TOF on the arrival time distributions of ubiquitin7+ and found conditions in which the native state prevails. We discuss the effects of solvent evaporation conditions in the source, of the entire pre-IM DC voltage gradient, of the funnel RF amplitudes. We also report on ubiquitin7+ conformations in different solvents, including native supercharging conditions. Collision-induced unfolding (CIU) can be conveniently provoked either behind the source capillary or in the trapping funnel. The softness of the instrumental conditions behind the mobility cell was further optimized with the DNA G-quadruplex [(dG4T4G4)2·(NH4+)3-8H]5−, for which ion activation results in ammonia loss. To reduce the ion internal energy and obtain the intact 3-NH4+ complex, we reduce the post-IM voltage gradient, but this results in a lower IM resolving power due to increased diffusion behind the drift tube. The article describes the various trade-offs between ion activation, ion transmission, and ion mobility performance for native MS of very fragile structures.Keywords
All Related Versions
Funding Information
- FP7 Ideas: European Research Council (616551)
This publication has 30 references indexed in Scilit:
- Supercharging Protein Complexes from Aqueous Solution Disrupts their Native ConformationsJournal of the American Society for Mass Spectrometry, 2011
- Collision Cross Sections of Proteins and Their Complexes: A Calibration Framework and Database for Gas-Phase Structural BiologyAnalytical Chemistry, 2010
- Ion mobility–mass spectrometry of phosphorylase B ions generated with supercharging reagents but in charge-reducing bufferPhysical Chemistry Chemical Physics, 2010
- Ion mobility–mass spectrometryJournal of Mass Spectrometry, 2008
- Enhanced Ion Utilization Efficiency Using an Electrodynamic Ion Funnel Trap as an Injection Mechanism for Ion Mobility SpectrometryAnalytical Chemistry, 2008
- Intermolecular Interactions in Biomolecular Systems Examined by Mass SpectrometryAnnual Review of Physical Chemistry, 2007
- Transfer of Structural Elements from Compact to Extended States in Unsolvated UbiquitinJournal of the American Chemical Society, 2006
- Internal energy and fragmentation of ions produced in electrospray sourcesMass Spectrometry Reviews, 2004
- Structural Transitions of Electrosprayed Ubiquitin Ions Stored in an Ion Trap over ∼10 ms to 30 sThe Journal of Physical Chemistry A, 2002
- The observation of non-covalent interactions in solution by electrospray ionization mass spectrometry: Promise, pitfalls and prognosisJournal of Mass Spectrometry, 1993