Background: During cardiogenic shock blood circulation is minimal in the human body and does not suffice to survive. The extracorporeal life support system (ECLS) acts as a miniature heart-lung-machine that can be temporarily implanted over major vessels e.g. at the groin of the patient to bridge cardiogenic shock. To perform this procedure in an emergency, a proper training model is desirable. Therefore, a 3-dimensional-printable (3D) material must be found that mimics large vessel needle penetration properties. A suitable test bench for material comparison is desirable. Methods: A test setup was built, which simulated the clinically relevant wall tension in specimens. The principle was derived from an existing standardized needle penetration test. After design, the setup was fabricated by means of 3D printing and mounted onto an universal testing machine. For testing the setup, a 3D printable polymer with low Shore A hardness and porcine aorta were used. The evaluation was made by comparing the curves of the penetration force to the standardized test considering the expected differences. Results: 3D printing proved to be suitable for manufacturing the test setup, which finally was able to mimic wall tension as if under blood pressure and penetration angle. The force displacement diagrams showed the expected curves and allowed a conclusion to the mechanical properties of the materials. Although the materials forces deviated between the porcine aorta and the Agilus30 polymer, the graphs showed similar but still characteristic curves. Conclusions: The test bench provided the expected results and was able to show the differences between the two materials. To improve the setup, limitations has been discussed and changes can be implemented without complications.Keywords
Funding Information
- Universitätsklinikum Tübingen
This publication has 9 references indexed in Scilit:
- ECMO implantation training: Needle penetration in 3D printable materials and porcine aortaPerfusion, 2020
- Design and fabrication of a generic 3D-printed silicone unilateral cleft lip and palate modelJournal of Plastic, Reconstructive & Aesthetic Surgery, 2019
- Experimental Mechanical Examination of Artificial 3D Printed and Post Processed Vascular Silicone Models2019
- Arterial Wall Penetration Forces in Needles versus CannulasPlastic and Reconstructive Surgery, 2019
- Determination of the Mechanical Properties of Aortic Tissue for 3D Printed Surgical Models2018
- Comparative Analysis of Porcine and Human Thoracic Aortic StiffnessEuropean Journal of Vascular and Endovascular Surgery, 2018
- Real‐time measurement of needle forces and acute pressure changes during intravitreal injectionsClinical & Experimental Ophthalmology, 2017
- Catheter replacement of the needle in percutaneous arteriographyActa Radiologica, 2008
- Extracorporeal life supportSeminars in Pediatric Surgery, 2006