High accuracy 3D data acquisition using co-registered OCT and kinect
Authors:
- 1 September 2016
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 32-37
Abstract
In many clinical scenarios, the spatial resolution of typical time-of-flight devices is not sufficient. Optical coherence tomography (OCT) presents an interesting high resolution modality with applications in image guided surgery and tissue characterization. However, the small field of view makes scanning larger areas difficult. We therefore consider co-registering a ToF depth camera (Kinect) with its large field-of-view but limited accuracy and OCT with its smaller field-of-view but very high accuracy. We study two approaches to obtain a registration between Kinect and OCT. The first approach is based on a novel marker and a direct registration between the two devices, either with or without using the construction of the novel marker. The second approach uses the marker to obtain a calibration between the OCT and a hexapod (Stewart platform) carrying it, and separate calibration between hexapod and Kinect. We show that the first approach typically results in better registration between Kinect and OCT with translational and rotational errors of (2.25 ± 1.23) mm and (1.54 ± 0.77)°, respectively. Furthermore, we demonstrate the use of the combined system to obtain a high resolution scan of the irregularly shaped surface of a head phantom.Keywords
This publication has 13 references indexed in Scilit:
- Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomographyBiomedical Optics Express, 2015
- An endoscopic structured light system using multispectral detectionInternational Journal of Computer Assisted Radiology and Surgery, 2015
- Comparative study on surface reconstruction accuracy of stereo imaging devices for microsurgeryInternational Journal of Computer Assisted Radiology and Surgery, 2015
- Learning Depth Calibration of Time-of-Flight Cameras2015
- Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgeryMedical Image Analysis, 2013
- Non‐orthogonal tool/flange and robot/world calibrationThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- Time-of-Flight 3-D Endoscopy2009
- Averaging QuaternionsJournal of Guidance, Control, and Dynamics, 2007
- Least-Squares Fitting of Two 3-D Point SetsIEEE Transactions on Pattern Analysis and Machine Intelligence, 1987
- Random sample consensusCommunications of the ACM, 1981