Field loss calculation of a wind‐powered axial flux alternator by analytical equations
Open Access
- 28 February 2021
- journal article
- research article
- Published by Wiley in Engineering Reports
- Vol. 3 (9) , e12391
Abstract
Various techniques have been investigated and proposed for core loss minimization in electrical machines. Nevertheless, many of such methods are mostly complicated and not suitable for consideration at a preliminary design stage. In this work, a simplified procedure which uses an analytical approach to minimizing the field's losses of an Axial Flux Permanent Magnet Alternator (AFPMA), is presented. First, the output equation of an AFPMA is referred, and then the minimization of the losses is investigated by analytical differential equations. The result of the derived‐specific magnetic loading is investigated using three different core materials, namely 35RM300, 50JN350, and 65JN800, and is found to reduce with increased frequencies. The 35RM300 core material gives the maximum specific magnetic loading and minimum power loss at investigated frequencies of 50 to 500 Hz. Although the 35RM300 core material gives the best performance, the optimal values are only determined as suitable by the manufacturer's design criteria. This study is a key indicator for a simple and efficient core material selection in the design of a Wind‐Powered AFPMA without the need for complicated analyses at the preliminary design stage.Keywords
This publication has 30 references indexed in Scilit:
- A Comprehensive Review of Axial-Flux Permanent-Magnet MachinesCanadian Journal of Electrical and Computer Engineering, 2014
- Theoretical and experimental analyses of a single phase permanent magnet generator (PMG) with multiple cores having axial and radial directed fluxesEnergy Conversion and Management, 2014
- Design and prototyping of an optimised axial‐flux permanent‐magnet synchronous machineIET Electric Power Applications, 2013
- ANALYSIS AND EXPERIMENTAL VERIFICATION OF LOSSES IN A CONCENTRATED WOUND INTERIOR PERMANENT MAGNET MACHINEProgress In Electromagnetics Research B, 2013
- IMPROVEMENT TO PERFORMANCE OF SOLID-ROTOR-RINGED LINE-START AXIAL-FLUX PERMANENT-MAGNET MOTORProgress In Electromagnetics Research, 2012
- AXIAL FLUX SURFACE MOUNTED PM MACHINE WITH FIELD WEAKENING CAPABILITY2007
- Axial-flux permanent-magnet air-cored generator for small-scale wind turbinesIEE Proceedings - Electric Power Applications, 2005
- Modeling of Axial Flux Permanent-Magnet MachinesIEEE Transactions on Industry Applications, 2004
- Developments in the processing and properties of NdFeb-type permanent magnetsJournal of Magnetism and Magnetic Materials, 2002
- Slotless permanent magnet synchronous motor operation without a high resolution rotor angle sensorIEEE Transactions on Energy Conversion, 2000