Development of a Fully Automated Peripheral Anterior Chamber Depth Analyzer and Evaluation of its Accuracy
Authors:
- Etsuko ShinbayashiESEtsuko Shinbayashi
- Shigeo TsukaharaSTShigeo Tsukahara
- 1 October 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 15 (5) , 388-393
Abstract
The aim of this study was to improve the scanning peripheral anterior chamber depth analyzer (SPAC) for measuring anterior chamber depth (ACD), differentiating eyes with shallow anterior chamber, and automatically categorizing eyes into subgroups based on the ACD values. We also investigated its accuracy for measuring anterior ocular biometry. The improved SPAC system was equipped with an auto-focusing system for measuring ACD from the optical axis to the limbus without contacting the ocular surface, in addition to an auto-measuring system for determining central corneal thickness (CCT) and corneal radius of curvature (CRC). This system was also equipped with an auto-diagnosing program for differentiating eyes with narrow angle and an auto-classifying program for categorizing eyes into 12 subgroups according to the ACD values. A dummy eye was used for investigating the measurement accuracy and reproducibility of CCT, CRC, and ACD. Measurement duration and clinical availability were investigated using healthy subjects and glaucoma patients. The SPAC-measured CCT, CRC, and ACD values were very similar to the theoretical values obtained from the dummy eye and their coefficients of variation were less than 1%. This system completed ACD measurement in 15.6+/-1.0 seconds and the mean coefficient of variation of ACD was 8.8+/-2.3%. The improved SPAC system successfully differentiated eyes with narrow angle from those with wide open angle. The improved SPAC system can measure ACD easily with good accuracy and reproducibility, and is considered to be suitable for evaluating ACD in routine examinations and screening eyes with narrow angle.Keywords
This publication has 7 references indexed in Scilit:
- Comparison of Optical Coherence Tomography and Ultrasound Biomicroscopy for Detection of Narrow Anterior Chamber AnglesArchives of Ophthalmology (1950), 2005
- Examination and Treatment of Patients with Angle-Closure Glaucoma in Japan: Results of a Nationwide SurveyJapanese Journal of Ophthalmology, 2004
- Acute primary angle closure in an asian populationOphthalmology, 2000
- Anterior Chamber Angle Biometry: A comparison of Scheimpf lug Photography and Ultrasound BiomicroscopyOphthalmic Research, 1995
- Ultrasound Biomicroscopy of Anterior Segment Structures in Normal and Glaucomatous EyesAmerican Journal of Ophthalmology, 1992
- Anterior Chamber Depth Measurement Using the Slit-Lamp MicroscopeAmerican Journal of Ophthalmology, 1979
- Estimation of Width of Angle of Anterior ChamberAmerican Journal of Ophthalmology, 1969