Optimizing timing performance of CdTe detectors for PET
Author:
Open Access
- 12 September 2017
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (19) , N485-N505
Abstract
Despite several attractive properties, the poor timing performance of compound semiconductor detectors such as CdTe and CdZnTe has hindered their use in commercial PET imaging systems. The standard method of pulse timing with such detectors is to employ a constant-fraction discriminator at the output of a timing filter which is fed by the pulses from a charge-sensitive preamplifier. The method has led to a time resolution of about 10 ns at full-width at half-maximum (FWHM) with 1 mm thick CdTe detectors. This paper presents a detailed investigation on the parameters limiting the timing performance of Ohmic contact planar CdTe detectors with the standard pulse timing method. The jitter and time-walk errors are studied through simulation and experimental measurements and it is revealed that the best timing results obtained with the standard timing method suffer from a significant loss of coincidence events (~50%). In order to improve the performance of the detectors with full detection efficiency, a new digital pulse timing method based on a simple pattern recognition technique was developed. A time resolution of 3.29 ± 0.10 ns (FWHM) in the energy range of 300–650 keV was achieved with an Ohmic contact planar CdTe detector (5 × 5 × 1 mm 3 ). The digital pulse processing method was also used to correct for the charge-trapping effect and an improvement in the energy resolution from 4.83 ± 0.66% to 2.780 ± 0.002% (FWHM) at 511 keV was achieved. Further improvement of time resolution through a moderate cooling of the detector and the application of the method to other detector structures are also discussed.Keywords
This publication has 40 references indexed in Scilit:
- Recursive Algorithms for Real-Time Digital ${\rm CR}\!-\!({\rm RC})^{\rm n}$ Pulse ShapingIEEE Transactions on Nuclear Science, 2011
- Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PETPhysics in Medicine & Biology, 2011
- Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectorsPhysics in Medicine & Biology, 2010
- Time resolution measurement of avalanche counters using digital signal processing techniqueRadiation Measurements, 2008
- Preliminary report on the development of a high resolution PET camera using semiconductor detectorsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2005
- CdTe and CdZnTe detectors for timing measurementsIEEE Transactions on Nuclear Science, 2002
- Novel pulse-shape-analysis method by using similarityApplied Radiation and Isotopes, 1998
- Charge Transport in Arrays of Semiconductor Gamma-Ray DetectorsPhysical Review Letters, 1995
- Comparative study of the timing techniques currently employed with Ge detectorsNuclear Instruments and Methods, 1972
- Zum Mechanismus des lichtelektrischen Prim rstromes in isolierenden KristallenThe European Physical Journal A, 1932