The Effective Foot Length Ratio: A Potential Tool for Characterization and Evaluation of Prosthetic Feet
- 1 April 2004
- journal article
- research article
- Published by Wolters Kluwer Health in JPO Journal of Prosthetics and Orthotics
- Vol. 16 (2) , 41-45
Abstract
The purpose of this technical note is to introduce the effective foot length ratio (EFLR) as a possible measurement tool for evaluation of prosthetic feet. The EFLR multiplied by 100 provides the percentage of a foot that is effectively used during a walking step and may have clinical implications for step length and limb loading on the contralateral side. Prosthetic feet were manually rolled over a force platform while maintaining a constant level of force representative of a user’s weight. Effective foot lengths were measured by finding the distance from the heel of each prosthetic foot to the center of pressure in foot-based coordinates at a loading angle that represented the approximate shank angle at opposite heel contact during walking. The effective foot lengths were then normalized by overall foot length to determine the EFLR. EFLRs from 15 prosthetic feet used clinically during the 1990s are presented along with an estimate of the EFLR of the physiologic ankle–foot system. All prosthetic feet had EFLRs lower than the corresponding physiologic system, although some had ratios close to the physiologic system. The EFLRs for the prosthetic feet were between 0.63 and 0.81, whereas the EFLR estimated for the physiologic system was 0.83.Keywords
This publication has 12 references indexed in Scilit:
- Alignment of transtibial prostheses based on rollover shape principlesProsthetics and Orthotics International, 2003
- Prosthetic foot rollover shapes with implications for alignment of transtibial prosthesesProsthetics and Orthotics International, 2000
- Influence of prosthetic foot design on sound limb loading in adults with unilateral below-knee amputationsArchives of Physical Medicine and Rehabilitation, 1994
- Comprehensive analysis of dynamic elastic response feet: Seattle ankle/lite foot versus SACH footArchives of Physical Medicine and Rehabilitation, 1993
- Gait Analysis and Energy Cost of Below-Knee Amputees Wearing Six Different Prosthetic FeetJPO Journal of Prosthetics and Orthotics, 1992
- Functional evaluation by gait analysis of various ankle-foot assemblies used by below-knee amputeesProsthetics and Orthotics International, 1992
- Gait Comparisons for Below-Knee Amputees Using a Flex-Foot??? Versus a Conventional Prosthetic FootJPO Journal of Prosthetics and Orthotics, 1991
- Below-knee amputee gait with dynamic elastic response prosthetic feet: A pilot studyJournal of Rehabilitation Research and Development, 1990
- Ankle-foot orthoses: Effect on gait abnormalities in tibial nerve paralysisArchives of Physical Medicine and Rehabilitation, 1985
- Role of the posterior calf muscles in normal gait.Journal of Bone and Joint Surgery, 1978