Abstract
This paper presents the response of a commercial off-the-shelf complementary metal oxide semiconductor (CMOS) active pixel sensor (APS) module to γ-rays delivered from Cobalt-60 at a high dose rate, and evaluates its performance as a potential high-dose-rate and wide range γ-ray detection device. The experimental results show that the rate of noise generation is not linear with respect to the total ionizing dose, and the radiation damage sustained by the sensor modules exhibits a total ionizing dose threshold. A conservative value of this threshold for the test sensor is 38 Gy. In addition, the average pixel gray level value and the proportion of pixels responding to radiation increase with increasing dose rate, and linear responses are obtained for both in the dose rate range of 5.24 to 69.24 Gy/h. the upper limit of the linear radiation response range depends on the capability of the COTS sensor module, while the lower limit depends on the number of radiation response events in a frame, and the upper limit of the linear response range can be increased by reducing the integration time. This work provides valuable suggestions for adopting CMOS-APSs for high-dose-rate and wide range radiation detection, and it is an important complement to our previous studies focused on the linear response of the CMOS-APS under low-dose-rate irradiation.
Funding Information
  • Hunan Provincial Key Laboratory of Emergency Safety Technology and Equipment for Nuclear Facilities
  • University of South China
  • Major Science and Technology Projects in Hunan Province Program (2012FJ1007)

This publication has 10 references indexed in Scilit: