Detection of Rotor Faults in Field Oriented Controlled Induction Machines
Authors:
- 1 October 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Industry Applications Annual Meeting
- Vol. 5 (01972618) , 2326-2332
Abstract
This work proposes an online method to diagnose rotor faults due to broken bars in induction machines controlled by a field oriented control scheme. First, control variables are analyzed under the presence of rotor faults. Then, the torque related stator current is proposed as the most suitable indicator. Sensitivity and reliability of this indicator are tested within the normal range of operation. Simulated and experimental results corroborate the proposalKeywords
This publication has 6 references indexed in Scilit:
- Online Diagnostics in Inverter-Fed Induction Machines Using High-Frequency Signal InjectionIEEE Transactions on Industry Applications, 2004
- The integration of machine fault detection into an indirect field oriented induction machine drive control scheme-the Vienna Monitoring Method2002
- Current Signature Analysis to Detect Induction Motor FaultsIEEE Industry Applications Magazine, 2001
- Transient analysis of cage induction machines under stator, rotor bar and end ring faultsIEEE Transactions on Energy Conversion, 1995
- Effects of time-varying loads on rotor fault detection in induction machinesIEEE Transactions on Industry Applications, 1995
- Der Stabbruch im Käfiǵläufer eines AsynchronmotorsElectrical Engineering, 1984