Optimisation on the thermal insulation layer thickness in buildings with environmental analysis: an updated comprehensive study for Turkey’s all provinces
- 1 July 2021
- journal article
- research article
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 7 (5) , 1239-1256
Abstract
This study determines the optimum insulation layer thickness to be applied to external building walls considering the heating degree-day (HDD) method, then energy saving costs, payback periods, and carbon dioxide (CO2) emissions are calculated accordingly. The optimisation analysis is performed for four different thermal insulation materials (glass wool, rock wool, extruded polystyrene, and expanded polystyrene). Natural gas is chosen as fuel for heating purposes, and horizontal perforated brick is preferred in the wall. One of the original features in this study is environmental analysis to determine the CO2 emission for the insulated wall in Turkey provinces. Another feature is that it has the most up-to-date data about HDD values and fuel and insulation material costs. The worst and best insulation materials are obtained as rock wool and glass wool, respectively. The optimum insulation layer thickness for the best case is varied between 0.07 m and 0.23 m, depending on the HDD values of provinces. The annual total energy saving cost is in the range of 4.4–53.5 $/(m2year), and the payback period is 0.11–0.38 years. Besides, the reduction in annual CO2 emission is changed between 53.2% and 94% for the best case, compared to the uninsulated wall.Keywords
This publication has 35 references indexed in Scilit:
- Thermal performance and optimum insulation thickness of building walls with different structure materialsApplied Thermal Engineering, 2011
- Thermoeconomic analysis method for optimization of insulation thickness for the four different climatic regions of TurkeyEnergy, 2010
- Effect of fuel type on the optimum thickness of selected insulation materials for the four different climatic regions of TurkeyApplied Energy, 2009
- Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of TurkeyBuilding and Environment, 2008
- The environmental impact of optimum insulation thickness for external walls of buildingsBuilding and Environment, 2007
- Determination of optimum insulation thicknesses of the external walls and roof (ceiling) for Turkey's different degree-day regionsEnergy Policy, 2007
- Optimization of insulation thickness for external walls using different energy-sourcesApplied Energy, 2006
- Determination of optimum insulation thickness for building walls with respect to various fuels and climate zones in TurkeyApplied Thermal Engineering, 2006
- Environmental impact of thermal insulation thickness in buildingsApplied Thermal Engineering, 2004
- Optimum insulation thickness of external walls for energy savingApplied Thermal Engineering, 2003