Reliability of Thoracic Spine Rotation Range-of-Motion Measurements in Healthy Adults
- 1 January 2012
- journal article
- Published by National Athletic Trainers' Association in Journal of Athletic Training
- Vol. 47 (1) , 52-60
Abstract
Context: The reliability of clinical techniques to quantify thoracic spine rotation range of motion (ROM) has not been evaluated. Objective: To determine the intratester and intertester reliability of 5 thoracic rotation measurement techniques. Design: Descriptive laboratory study. Setting: University research laboratory. Patients or Other Participants: Forty-six healthy volunteers (age = 23.6±4.3 years, height = 171.0±9.6 cm, mass = 71.4 ±16.7 kg). Main Outcome Measure(s): We tested 5 thoracic rotation ROM techniques over 2 days: seated rotation (bar in back and front), half-kneeling rotation (bar in back and front), and lumbar-locked rotation. On day 1, 2 examiners obtained 2 sets of measurements (sessions 1, 2) to determine the within-session intertester reliability and within-day intratester reliability. A single examiner obtained measurements on day 2 (session 3) to determine the intratester reliability between days. Each technique was performed 3 times per side, and averages were used for data analysis. Reliability was determined using intraclass correlation coefficients, standard error of measurement (SEM), and minimal detectable change (MDC). Differences between raters during session 1 were determined using paired t tests. Results: Within-session intertester reliability estimates ranged from 0.85 to 0.94. Ranges for the SEM were 1.0° to 2.3° and for the MDC were 2.8° to 6.3°. No differences were seen between examiners during session 1 for seated rotation (bar in front, both sides), half-kneeling rotation (bar in front, left side), or the lumbar locked position (both sides) (all values of P > .05). Within-day intratester reliability estimates ranged from 0.86 to 0.95. Ranges for the SEM were 0.8° to 2.1° and for the MDC were 2.1 ° to 5. 9°. Between-days intratester reliability estimates ranged from 0.84 to 0.91. Ranges for the SEM were 1.4° to 2.0° and for the MDC were 3.9° to 5.6°. Conclusions: All techniques had good reliability and low levels of measurement error. The seated rotation, bar in front, and lumbar-locked rotation tests may be used reliably when more than 1 examiner is obtaining measurements.Keywords
This publication has 20 references indexed in Scilit:
- Stability and intra-tester reliability of an in vivo measurement of thoracic axial rotation using an innovative methodologyManual Therapy, 2009
- Reproducibility and validity of digital inclinometry for measuring cervical range of motion in normal subjectsPhysiotherapy Research International, 2009
- Inter- and Intrarater Reliability of a Back Range of Motion InstrumentArchives of Physical Medicine and Rehabilitation, 2005
- Quantifying Test-Retest Reliability Using the Intraclass Correlation Coefficient and the SEMJournal of Strength & Conditioning Research, 2005
- A new skin-surface device for measuring the curvature and global and segmental ranges of motion of the spine: reliability of measurements and comparison with data reviewed from the literatureEuropean Spine Journal, 2004
- Measures of Shoulder Protraction and Thoracolumbar RotationJournal of Orthopaedic & Sports Physical Therapy, 1997
- An in vivo study of the primary and coupled rotations of the thoracic spineClinical Biomechanics, 1996
- A Comparative Study of Computed Tomographic and Plain Radiographic Methods to Measure Vertebral Rotation in Adolescent Idiopathic ScoliosisSpine, 1992
- A Comparison of Four Computerized Methods for Measuring Vertebral RotationSpine, 1990
- MEASUREMENT OF SPINAL POSTURE AND RANGE OF SPINAL MOVEMENTRheumatology, 1967