Wearability Testing of Ambulatory Vital Sign Monitoring Devices: Prospective Observational Cohort Study
Open Access
- 16 December 2020
- journal article
- research article
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 8 (12) , e20214
Abstract
Background: Timely recognition of patient deterioration remains challenging. Ambulatory monitoring systems (AMSs) may provide support to current monitoring practices; however, they need to be thoroughly tested before implementation in the clinical environment for early detection of deterioration. Objective: The objective of this study was to assess the wearability of a selection of commercially available AMSs to inform a future prospective study of ambulatory vital sign monitors in an acute hospital ward. Methods: Five pulse oximeters (4 with finger probes and 1 wrist-worn only, collecting pulse rates and oxygen saturation) and 2 chest patches (collecting heart rates and respiratory rates) were selected to be part of this study: The 2 chest-worn patches were VitalPatch (VitalConnect) and Peerbridge Cor (Peerbridge); the 4 wrist-worn devices with finger probe were Nonin WristOx2 3150 (Nonin), Checkme O2+ (Viatom Technology), PC-68B, and AP-20 (both from Creative Medical); and the 1 solely wrist-worn device was Wavelet (Wavelet Health). Adult participants wore each device for up to 72 hours while performing usual “activities of daily living” and were asked to score the perceived exertion and perception of pain or discomfort by using the Borg CR-10 scale; thoughts and feelings caused by the AMS using the Comfort Rating Scale (CRS); and to provide general free text feedback. Median and IQRs were reported and nonparametric tests were used to assess differences between the devices’ CRS scores. Results: Quantitative scores and feedback were collected in 70 completed questionnaires from 20 healthy volunteers, with each device tested approximately 10 times. The Wavelet seemed to be the most wearable device (P<.001) with an overall median (IQR) CRS score of 1.00 (0.88). There were no statistically significant differences in wearability between the chest patches in the CRS total score; however, the VitalPatch was superior in the Attachment section (P=.04) with a median (IQR) score of 3.00 (1.00). General pain and discomfort scores and total percentage of time worn are also reflective of this. Conclusions: Our results suggest that adult participants prefer to wear wrist-worn pulse oximeters without a probe compressing the fingertip and they prefer to wear a smaller chest patch. A compromise between wearability, reliability, and accuracy should be made for successful and practical integration of AMSs within the hospital environment.Keywords
All Related Versions
This publication has 30 references indexed in Scilit:
- What is the nursing time and workload involved in taking and recording patients’ vital signs? A systematic reviewJournal of Clinical Nursing, 2020
- Nurses’ 12-hour shifts and missed or delayed vital signs observations on hospital wards: retrospective observational studyBMJ Open, 2019
- The association between nurse staffing and omissions in nursing care: A systematic reviewJournal of Advanced Nursing, 2018
- Strengths and limitations of early warning scores: A systematic review and narrative synthesisInternational Journal of Nursing Studies, 2017
- Effectiveness of continuous or intermittent vital signs monitoring in preventing adverse events on general wards: a systematic review and meta-analysisInternational Journal Of Clinical Practice, 2016
- ‘Errors’ and omissions in paper-based early warning scores: the association with changes in vital signs—a database analysisBMJ Open, 2015
- Detecting critical illness outside the ICU: the role of track and trigger systemsCurrent Opinion in Critical Care, 2010
- A randomised controlled trial of the effect of continuous electronic physiological monitoring on the adverse event rate in high risk medical and surgical patientsAnaesthesia, 2006
- Integrated monitoring and analysis for early warning of patient deteriorationBritish Journal of Anaesthesia, 2006
- Confidential inquiry into quality of care before admission to intensive careBMJ, 1998