Arteriovenous Fistulas for Hemodialysis: Application of High-Frequency US to Assess Vein Wall Morphology for Cannulation Readiness
Authors:
- Derek MuradaliDMDerek Muradali
- Rosa M. MarticorenaRMRosa M. Marticorena
- Niki DacourisNDNiki Dacouris
- Adrien BoutinABAdrien Boutin
- Anna M. MulliganAMAnna M. Mulligan
- Peter D. BallykPBPeter D. Ballyk
- Vikramaditya PrabhudesaiVPVikramaditya Prabhudesai
- Vern M. CampbellVCVern M. Campbell
- Sandra M. DonnellySDSandra M. Donnelly
- 1 November 2011
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 261 (2) , 616-624
Abstract
To determine whether venous wall thickness and hoop (circumferential) stress, as determined with high-frequency ultrasonography (US), can predict cannulation readiness in arteriovenous fistulas (AVFs). Institutional review board approval and informed consent were obtained for this prospective study. To determine the US appearance of the venous wall, an AVF specimen was excised and scanned in a bath of degassed lactated Ringer solution with a 55-MHz probe. The appearance of the wall at high-frequency US was correlated with histologic findings. High-frequency (40-55-MHz) US was used to image the near-field AVF venous wall of 14 men (mean age, 59 years ± 11 [standard deviation]) and six women (mean age, 55 years ± 14) with newly created AVFs within 1 week of cannulation between January 2008 and December 2009. Measurements of the intima-media thickness (IMT) were generated by three independent observers who were blinded to outcomes. Intraclass correlation analysis was performed. Cannulation readiness was defined as no extravasation during the first dialysis treatment. By using high-frequency US, the IMT was defined as the sum of a thin echogenic blood-intima interface and a uniform hypoechoic media. The mean IMT of the no extravasation group (0.16 mm ± 0.03) was greater than that of the extravasation group (0.10 mm ± 0.02) (P < .001). A minimum threshold IMT of 0.13 mm (P < .001) was associated with successful cannulation. The mean hoop stress of the no extravasation group (246 kPa ± 57) was lower than that of the extravasation group (530 kPa ± 199) (P < .001). A maximum hoop stress threshold of 248 kPa was associated with successful cannulation (P = .009). Venous IMT and hoop stress assessed with high-frequency US can predict cannulation readiness in AVFs that are clinically deemed mature.Keywords
This publication has 35 references indexed in Scilit:
- Why don't fistulas mature?Kidney International, 2006
- Vascular access for hemodialysisNature Clinical Practice Nephrology, 2006
- Early Arteriovenous Fistula FailureClinical Journal of the American Society of Nephrology, 2006
- Overcoming Barriers to Arteriovenous Fistula Creation and UseSeminars in Dialysis, 2003
- Increasing arteriovenous fistulas in hemodialysis patients: Problems and solutionsKidney International, 2002
- Cost analysis of ongoing care of patients with end-stage renal disease: The impact of dialysis modality and dialysis accessAmerican Journal of Kidney Diseases, 2002
- Vascular access use in Europe and the United States: Results from the DOPPSKidney International, 2002
- Physical Examination of the Dialysis Vascular AccessSeminars in Dialysis, 1998
- Vascular access survival among incident hemodialysis patients in the United StatesAmerican Journal of Kidney Diseases, 1997