Labial bone assessment surrounding dental implant using cone-beam computed tomography: an in vitro study
- 3 August 2011
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 23 (8) , 970-974
Abstract
Objective Stable esthetic restoration is required for anterior dental implants, assessed over a long-term follow-up. Cross-sectional images obtained using cone-beam computed tomography (CBCT) allow visualization of the bucco-lingual bone surrounding dental implants; however, the thin labial bone surrounding anterior dental implants is unclear. So, the minimum labial bone thickness surrounding dental implants detected using CBCT images was estimated in the present in vitro study. Materials and methods One dry mandible with five aluminum steps and a titanium rod for simulation of the thin labial bone and dental implant were used. CBCT was performed three times using three exposure volumes, and voxel values of each aluminum step were plotted. Then, the maximum voxel value in each aluminum step as a percentage of that of the 1-mm-thick aluminum step was calculated. Results The rates for the 0.6-mm-thick aluminum step with a 51- and 102-mm-diameter exposure volume were approximately 50% or greater. Conclusions When labial bone surrounding the dental implant was approximately 0.6 mm or greater, it was suggested that it might be visually detectable using CBCT images with a 51- and 102-mm-diameter exposure volume.Keywords
This publication has 10 references indexed in Scilit:
- Postoperative Assessment of Incisor Dental Implants Using Cone-Beam Computed TomographyJournal of Oral Implantology, 2010
- Evaluation of voxel values in mandibular cancellous bone: relationship between cone‐beam computed tomography and multislice helical computed tomographyClinical Oral Implants Research, 2009
- In vitro perception of low-contrast features in digital, film, and digitized dental radiographs: A receiver operating characteristic analysisOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Imaging artifact and exposure conditions in limited-volume cone-beam computed tomography: comparison between an image intensifier system and a flat panel detectorOral Radiology, 2006
- Computed Tomography for oral and Maxillofacial Surgeons. Part 2: Cone-beam Computed TomographyAsian Journal of Oral and Maxillofacial Surgery, 2006
- Image artifact in dental cone-beam CTOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2006
- Postoperative Tomographic Assessment of Veneer Bone Grafting with Implant Placement in the Maxillary Anterior RegionImplant Dentistry, 2005
- Single Implants and Buccal Bone Grafts in the Anterior Maxilla: Measurements of Buccal Crestal Contours in a 6-Year Prospective Clinical StudyClinical Implant Dentistry and Related Research, 2005
- OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM ImagesJournal of Digital Imaging, 2004
- Assessment of image quality in dental radiography, part 1Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 1999