Heat transfer and frost formation inside a liquid nitrogen‐cooled tube
Authors:
- 1 November 1966
- journal article
- research article
- Published by Wiley in AIChE Journal
- Vol. 12 (6) , 1190-1195
Abstract
An experimental study was undertaken of simultaneous heat transfer and frost deposition inside a liquid nitrogen‐cooled tube for a range of humidities and Reynolds numbers. The data indicate that diffusion of water vapor within the frost layer caused the frost density and thermal conductivity to increase with time. The increase was so great that the heat transfer rate became constant even while frost continued to accumulate. In a separate study the thermal conductivities of frosts formed on a cryogenic surface were measured and found to be lower than values near the freezing point of water.Keywords
This publication has 8 references indexed in Scilit:
- Heat, Mass, and Momentum Transfer Inside Frosted Tubes—Experiment and TheoryJournal of Heat Transfer, 1964
- Analysis of the Frost Phenomena on a Cryo-Surface1964
- A Study of Heat and Mass Transfer to Uninsulated Liquid Oxygen Containers1961
- Freeze Out Purification of Gases in Heat Exchangers1960
- Atmospheric Heat Transfer to Vertical Tanks Filled with Liquid Oxygen1960
- Fog Formation in Cooler-CondensersIndustrial & Engineering Chemistry, 1950
- Heat transfer at low temperatures between tube walls and gases in turbulent flowProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1947
- L’économie radio-thermique des champs de neige et des glaciersAnnales de Physique, 1933