Rotational alignment in total knee arthroplasty: intraoperative inter- and intraobserver reliability of Whiteside’s line
- 8 June 2011
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 131 (11) , 1477-1480
Abstract
Introduction Proper rotational alignment is a critical step of total knee arthroplasty. For intraoperative determination of femoral rotation, Whiteside suggests a perpendicular line to the axis of the center of the trochlea and the intercondylar notch (Whiteside’s line). Method In a prospective clinical study, the intraoperative position of Whiteside’s line was measured in 30 patients with the help of a navigation system. Results Whiteside’s line was 2.1° ± 1.5° externally rotated compared to a navigation based computer calculated preliminary AP axis of the femur. The intraobserver-reliability after 3 repeated measurements each was 1.6° for the senior surgeon and 1.4° for the junior surgeon (p = 0.598, p = 0.968). The interobserver reliability between the measurements by the senior and junior surgeon was 1.4° (p = 0.547). Conclusion Navigated intraoperative measurements of Whiteside’s line showed a high inter- and intraobserver reliability. Considering the variability between Whiteside’s line and the transepicondylar axis, intraoperative assessment of both the methods is recommended.Keywords
This publication has 23 references indexed in Scilit:
- Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tensionThe Knee, 2010
- A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgeryInternational Orthopaedics, 2010
- Gap Balancing versus Measured Resection Technique for Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2010
- A common reference frame for describing rotation of the distal femurThe Journal of Bone and Joint Surgery. British volume, 2009
- Navigation Improves Accuracy of Rotational Alignment in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2004
- Low reproducibility of the intra–operative measurement of the transepicondylar axis during total knee replacementActa Orthopaedica, 2004
- Femoral Component Rotation During Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1999
- Femoral Rotational Alignment Using the Tibial Shaft Axis in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996
- Rotational Landmarks and Sizing of the Distal Femur in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1996
- Anatomic Alignment of the Patellar GrooveClinical Orthopaedics and Related Research, 1996