Relay Fault Diagnosis for Electric Heavy Trucks Based on Operating State Transition Rule and Feature Space Topological Analysis Classifier

Authors:

Abstract
Accurate relay fault diagnosis in electric heavy trucks’ High-Voltage Power Distribution Systems (HV PDS) is critical for safety, yet challenged by the high hardware cost of multi-channel sensing and the trade-off between robustness and computational efficiency in existing methods. This paper proposes a simplified monitoring system using only bus current and voltage signals, introducing a novel diagnosis method based on Operating State Transition Rules and a Feature Space Topological Analysis Classifier (FSTAC). First, state transition rules logically localize actuating relays through multi-domain feature analysis without extra sensors. Second, a cross-frame feature fusion mechanism extracts complementary time-frequency features for three typical faults, which are classified by the low-cost FSTAC algorithm. Benchmarked against traditional thresholding and deep learning models, experiments demonstrate that our approach achieves 98.69% localization and 99.25% diagnosis accuracy with merely 0.07s inference time. These results confirm the method’s superior balance of precision, robustness, and real-time ease of deployment for onboard HV systems.
Funding Information
  • Henan Provincial Technology Deputy Directors Program
  • Innovation Funds Plan of Henan University of Technology (2021ZKCJ07)

This publication has 22 references indexed in Scilit: