Implementation of a New Protocol for Direct Identification from Urine in the Routine Microbiological Diagnosis
Open Access
- 26 April 2022
- journal article
- research article
- Published by MDPI AG in Antibiotics
- Vol. 11 (5) , 582
Abstract
Background: The direct identification of uropathogens from urine samples, in combination with the rapid detection of resistance, would allow early adjustment of empirical antimicrobial treatment. Methods: Two hundred and ninety-eight urine samples processed between 1 June and 31 December 2020, selected with flow cytometry, with direct identification by MALDI-TOF mass spectrometry, and rapid detection of extended-spectrum beta-lactamase (ESBL) and carbapenemases-producing strains by lateral flow were analyzed. Results: The positive predictive value of the direct identification of the 86 samples that met the flow cytometry criterion (>5000 bacteria/µL) was 96.4%. Reliable direct identification was obtained in 14 of the 27 (51.8%) urinary source bacteraemias. There was 100% agreement between the lateral flow and antibiogram in the detection of ESBL and carbapenemases. Conclusion: the protocol for the direct identification and rapid detection of ESBL and carbapenemases-producing strains from urine samples is a reliable and useful tool.Keywords
This publication has 14 references indexed in Scilit:
- Development of a new protocol for rapid bacterial identification and susceptibility testing directly from urine samplesClinical Microbiology and Infection, 2016
- CTX-M-15-H30Rx-ST131 subclone is one of the main causes of healthcare-associated ESBL-producingEscherichia colibacteraemia of urinary origin in SpainJournal of Antimicrobial Chemotherapy, 2016
- Rapid urine preparation prior to identification of uropathogens by MALDI-TOF MSEuropean Journal of Clinical Microbiology & Infectious Diseases, 2015
- New procedure for rapid identification of microorganisms causing urinary tract infection from urine samples by mass spectrometry (MALDI-TOF)Enfermedades Infecciosas y Microbiología Clínica, 2015
- Pretreatment of Urine Samples with SDS Improves Direct Identification of Urinary Tract Pathogens with Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass SpectrometryJournal of Clinical Microbiology, 2014
- Procedure for microbial identification based on Matrix‐Assisted Laser Desorption/Ionization‐Time of Flight Mass Spectrometry from screening‐positive urine samplesAPMIS, 2013
- Direct identification of bacteria causing urinary tract infections by combining matrix-assisted laser desorption ionization-time of flight mass spectrometry with UF-1000i urine flow cytometryJournal of Microbiological Methods, 2013
- Matrix-assisted laser desorption ionization time-of-flight mass spectrometry identifies 90% of bacteria directly from blood culture vialsClinical Microbiology and Infection, 2010
- Direct Identification of Urinary Tract Pathogens from Urine Samples by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass SpectrometryJournal of Clinical Microbiology, 2010
- Direct Identification of Bacteria in Positive Blood Culture Bottles by Matrix-Assisted Laser Desorption Ionisation Time-of-Flight Mass SpectrometryPLOS ONE, 2009