Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study
Authors:
- 23 March 2024
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 144 (5) , 2131-2140
Abstract
Introduction Treatment of both simple and complex patella fractures is a challenging clinical problem. Although tension band wiring has been the standard of care, it can be associated with high complication rates. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Materials and methods Sixteen pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior (central distal) fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full extension. Interfragmentary movements were captured via motion tracking. Results For both fracture types, the articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p ≤ 0.01. Conclusions From a biomechanical perspective, lateral rim variable angle locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading.Keywords
This publication has 42 references indexed in Scilit:
- A novel patella fracture fixation technique: finite element analysisArchives of orthopaedic and trauma surgery, 2023
- Treatment of inferior pole patella fracture using Krackow suturing combined with the suture bridge techniqueArchives of orthopaedic and trauma surgery, 2022
- 3D reduction combined with the modified Kirschner-wire tension band for the treatment of comminuted patella fractureArchives of orthopaedic and trauma surgery, 2022
- PatellafrakturenDer Unfallchirurg, 2010
- Biomechanical comparison of a new staple technique with tension band wiring for transverse patella fracturesClinical Biomechanics, 2009
- Tension-band wiring of transverse fractures of patella. The effect of site of wire twists and orientation of stainless steel wire loop: a biomechanical investigationInternational Orthopaedics, 2006
- Guidelines for the clinical application of the LCPInjury, 2003
- Frakturen der KniescheibeTrauma und Berufskrankheit, 2002
- Probleme der Zuggurtungsosteosynthese von Patellafrakturen und deren Konsequenzen für weitere Implantatentwicklungen Der XS-NagelDer Chirurg, 2001
- Überraschende Erfolge durch die Anwendung einer Zuggurtung bei der PatellarfrakturLangenbeck's Archives of Surgery, 1966