Conditions for Direct Applicability of Electronic Capacitors to Dual-Stage Grid-Connected Power Conversion Systems
Authors:
- A. MutovkinAMA. Mutovkin
- M. MellincovskyMMM. Mellincovsky
- V. YuhimenkoVYV. Yuhimenko
- S. SchachamSSS. Schacham
- A. KupermanA. Kuperman
- 25 April 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 7 (3) , 1805-1814
Abstract
Active capacitance reduction circuits (ACRC) are DC-DC converters, terminated by a small auxiliary capacitor, typically utilized to replace bulk electrolytic capacitors in dual-stage grid-connected power conversion systems. Electronic Capacitors are ACRCs supporting "plug-and-play" operation in addition to the ability of emulation virtually any finite capacitance at DC-link connected terminals. Despite excellent steady-state functionality, all ACRCs possess poor response to step-like no load – to – full load (and vice-versa) transients due to the fact that the auxiliary capacitor utilized (and thus corresponding energy stored) is much smaller than the bulk DC link capacitor being replaced. Nevertheless, in grid-feeding applications where fuel cells of photovoltaic generators act as power source, rate of generated power change is limited. This is also true regarding some off-grid systems such as LED lightning with dimming, where sudden load changes are unnecessary and Electronic Capacitors seem to be directly applicable in such systems. Therefore, this paper reveals the limits of step-like and ramp-like load variations, tolerable by a system equipped with an Electronic Capacitor, based on its power rating and auxiliary capacitance value utilized. Examples are given for typical systems with 400V DC link, connected to 50Hz mains. Validity of presented findings is well-supported by simulations and experiments.Keywords
Funding Information
- Ministry of National Infrastructure, Energy and Water Resources
This publication has 40 references indexed in Scilit:
- A SiC-Based High Power Density Single-Phase Inverter With In-Series and In-Parallel Power Decoupling MethodIEEE Journal of Emerging and Selected Topics in Power Electronics, 2016
- A Modified Reference of an Intermediate Bus Capacitor Voltage-Based Second-Harmonic Current Reduction Method for a Standalone Photovoltaic Power SystemIEEE Transactions on Power Electronics, 2015
- Benchmark of AC and DC Active Power Decoupling Circuits for Second-Order Harmonic Mitigation in Kilowatt-Scale Single-Phase InvertersIEEE Journal of Emerging and Selected Topics in Power Electronics, 2015
- Improved adaptive input voltage control of a solar array interfacing current mode controlled boost power stageEnergy Conversion and Management, 2015
- Bus Voltage Control With Zero Distortion and High Bandwidth for Single-Phase Solar InvertersIEEE Transactions on Power Electronics, 2015
- On the Reduction of Second Harmonic Current and Improvement of Dynamic Response for Two-Stage Single-Phase InverterIEEE Transactions on Power Electronics, 2015
- Feed-Forward Scheme for an Electrolytic Capacitor-Less AC/DC LED Driver to Reduce Output Current RippleIEEE Transactions on Power Electronics, 2014
- Second-Harmonic Current Reduction and Dynamic Performance Improvement in the Two-Stage Inverters: An Output Impedance PerspectiveIEEE Transactions on Industrial Electronics, 2014
- Reliability of Capacitors for DC-Link Applications in Power Electronic Converters—An OverviewIEEE Transactions on Industry Applications, 2014
- Development of a Quick Dynamic Response Maximum Power Point Tracking Algorithm for Off-Grid System With Adaptive Switching (On–Off) Control of dc/dc ConverterJournal of Solar Energy Engineering, 2012