Double balloon protection during carotid artery stenting for vulnerable carotid stenosis reduces the incidence of new brain lesions
- 2 May 2016
- journal article
- research article
- Published by Springer Nature in Acta Neurochirurgica
- Vol. 158 (7) , 1377-1386
Abstract
Background The use of distal filter protection alone is associated with a high risk of ischemic complications when vulnerable carotid stenosis is treated by carotid artery stenting (CAS). Double balloon protection, a combination of distal balloon protection and proximal balloon occlusion, can be utilized. We assessed the outcome and complications of the double balloon protection method for vulnerable carotid stenosis. Methods Among 130 patients who underwent CAS from 2009 to 2014, we enrolled the following patients: those whose target lesion was vulnerable as evaluated by MRI, i.e., a signal ratio of plaque to posterior cervical muscle on T1-weighted images before CAS of ≥1.5, and those who underwent diffusion-weighted imaging (DWI) studies within 48 h after the procedure. Ninety patients were enrolled. We investigated DWI findings of the double balloon protection group compared with those of the simple distal balloon protection and distal filter protection groups. Results Sixty-four patients (71 %) underwent double balloon protection, 15 patients (17 %) simple distal balloon protection, and 11 patients (12 %) distal filter protection. Symptomatic embolic complications and new lesions on DWI after CAS were significantly less common in patients undergoing double balloon protection compared to distal balloon protection or distal filter protection (0 % vs. 20 %, 9 %, P < 0.01, and 30 % vs. 67 %, 82 %, P < 0.01, respectively). Logistic regression analysis also identified the odds ratio of double balloon protection for new lesions on DWI after CAS of 0.23 (95 % confidence interval: 0.07–0.70, P < 0.01) compared to simple distal protections. Conclusions In the patients who underwent CAS for vulnerable carotid stenosis, double balloon protection was an independent significant factor associated with a reduction in the risk of new lesions on DWI after the procedure compared to conventional distal protections.Keywords
This publication has 25 references indexed in Scilit:
- The PROFI Study (Prevention of Cerebral Embolization by Proximal Balloon Occlusion Compared to Filter Protection During Carotid Artery Stenting)JACC, 2012
- Long-term Angiographic and Clinical Outcome Following Stenting by Flow Reversal Technique for Chronic Occlusions Older Than 3 Months of the Cervical Carotid or Vertebral ArteryNeurosurgery, 2012
- Stenting versus Endarterectomy for Treatment of Carotid-Artery StenosisNew England Journal of Medicine, 2010
- Safety and effectiveness of the INVATEC MO.MA® proximal cerebral protection device during carotid artery stenting: Results from the ARMOUR pivotal trialCatheterization and Cardiovascular Interventions, 2010
- Endovascular recanalization of the completely occluded internal carotid artery using a flow reversal system at the subacute to chronic stageJournal of Neurosurgery, 2010
- Systematic Review of the Perioperative Risks of Stroke or Death After Carotid Angioplasty and StentingStroke, 2009
- New Brain Lesions After Carotid Stenting Versus Carotid EndarterectomyStroke, 2008
- Characterization of Carotid Atherosclerosis and Detection of Soft Plaque with Use of Black-Blood MR ImagingAmerican Journal of Neuroradiology, 2008
- Incidence of New Brain Lesions After Carotid Stenting With and Without Cerebral ProtectionStroke, 2006
- Analysis of Emboli during Carotid Stenting with Distal Protection DeviceCerebrovascular Diseases, 2006